MAX11014 Datasheet, PDF (43/69 Pages) Maxim Integrated Products – Automatic RF MESFET Amplifier Drain-Current Controllers
Automatic RF MESFET Amplifier
Drain-Current Controllers
Table 14. VSET1 and VSET2 (Write)
BIT NAME
X
VSET11–VSET0
DATA BIT
D15–D12
D11–D0
RESET STATE
X
0000 0000 0000
FUNCTION
Don’t care.
VSET11 is the MSB and VSET0 is the LSB. Data format is straight binary.
Table 15. USRK1 and USRK2 (Write)
BIT NAME
X
K11–K0
DATA BIT
D15–D12
D11–D0
RESET STATE
X
N/A
FUNCTION
Don’t care.
K11 is the MSB and K0 is the LSB. Data format is straight binary.
Set the VALARM1 bit, D5, to 1 to enable alarm function-
ality for GATE1 voltage measurements. Set the VWIN1
bit, D4, to 1 to monitor the GATE1 voltage with the
ALARM comparator in windowing mode. Set VWIN1 to 0
to monitor the GATE1 voltage with the ALARM compara-
tor in hysteresis mode. Set the TALARM1 bit, D3, to 1 to
enable alarm functionality for channel 1 temperature
measurements. Set the TWIN1 bit, D2, to 1 to monitor the
channel 1 temperature with the ALARM comparator in
windowing mode. Set TWIN1 to 0 to monitor the channel
1 temperature with the ALARM comparator in hysteresis
mode. Set the IALARM1 bit, D1, to 1 to enable alarm
functionality for channel 1 sense voltage (RCS1+ to
RCS1-) measurements. Set the IWIN1 bit, D0, to 1 to
monitor the channel 1 sense voltage with the ALARM
comparator in windowing mode. Set IWIN1 to 0 to moni-
tor the channel 1 sense voltage with the ALARM com-
parator in hysteresis mode.
VSET1 and VSET2 (Write)
Write to the channel 1/channel 2 VSET registers to set
the VSET(CODE) code in the VDAC(CODE) equations.
Writing to these registers triggers a VDAC(CODE) calcu-
lation. That code is then loaded into either the channel
1/channel 2 DAC input register or channel 1/channel 2
DAC input and output register, depending on the state
of the LDAC1/LDAC2 bits in the software configuration
register. Set the command byte to 40h to write to the
channel 1 VSET register. Set the command byte to 42h
to write to the channel 2 VSET register. See Table 14.
Bits D15–D12 are don’t care. Bits D11–D0 contain the
straight binary data.
USRK1 and USRK2 (Write)
Write to the channel 1/channel 2 K parameter registers
to set the LUTK[K] code in the VDAC(CODE) equation.
The K parameter register value is loaded into the
VDAC(CODE) equation when the KSRC_ bits in the soft-
ware configuration register are set to 010, 101, 110, or
111. See Table 11b. Use the K parameter as an index
to the K LUT or as a multiplier for the VDAC(CODE)
equation in place of VSET(CODE) by writing to the soft-
ware configuration register. See Table 11. Set the com-
mand byte to 44h to write to the channel 1 K parameter
register. Set the command byte to 46h to write to the
channel 2 K parameter register. See Table 15. Bits
D15–D12 are don’t care. Bits D11–D0 contain the
straight binary data.
IPDAC1 and IPDAC2 (Write)
Write to the channel 1/channel 2 DAC input registers to
load the DAC code and bypass a VDAC(CODE) calcula-
tion. Transfer the code written to the DAC input registers
to the channel 1/channel 2 DAC output registers by set-
ting the corresponding DACCH_ bit high in the software
load DAC register. Set the command byte to 48h and
4Ch, respectively, to write to the channel 1/channel 2
DAC input registers. See Table 16. Bits D15–D12 are
don’t care. Bits D11–D0 contain the straight binary data.
Writing to these registers overwrites any previous val-
ues loaded from the VDAC(CODE) calculation.
______________________________________________________________________________________ 43