MAX11014 Datasheet, PDF (42/69 Pages) Maxim Integrated Products – Automatic RF MESFET Amplifier Drain-Current Controllers
Automatic RF MESFET Amplifier
Drain-Current Controllers
Table 13. ALMSCFG (Read/Write)
BIT NAME DATA BIT RESET STATE
X
D15–D12
X
Don’t care.
FUNCTION
VALARM2
D11
Channel 2 GATE voltage ALARM bit. Set to 1 to enable the alarm functionality for
0
GATE2 voltage measurements. Set to 0 to disable the alarm functionality for GATE2
voltage measurements.
VWIN2
D10
Channel 2 GATE voltage windowing bit. Set to 1 to monitor the GATE2 voltage with the
0
ALARM comparator in windowing mode. Set to 0 to monitor the GATE2 voltage with the
ALARM comparator in hysteresis mode.
TALARM2
D9
Channel 2 temperature ALARM bit. Set to 1 to enable the alarm functionality for
0
channel 2 temperature measurements. Set to 0 to disable the alarm functionality for
channel 2 temperature measurements.
TWIN2
D8
Channel 2 temperature windowing bit. Set to 1 to monitor the channel 2 temperature
0
with the ALARM comparator in windowing mode. Set to 0 to monitor the channel 2
temperature with the ALARM comparator in hysteresis mode.
IALARM2
D7
Channel 2 sense voltage ALARM bit. Set to 1 to enable the alarm functionality for
0
channel 2 sense voltage measurements. Set to 0 to disable the alarm functionality for
channel 2 sense voltage measurements.
IWIN2
D6
Channel 2 sense voltage windowing bit. Set to 1 to monitor the channel 2 sense
0
voltage with the ALARM comparator in windowing mode. Set to 0 to monitor the
channel 2 sense voltage with the ALARM comparator in hysteresis mode.
VALARM1
D5
Channel 1 GATE voltage ALARM bit. Set to 1 to enable the alarm functionality for
0
GATE1 voltage measurements. Set to 0 to disable the alarm functionality for GATE1
voltage measurements.
VWIN1
D4
Channel 1 GATE voltage windowing bit. Set to 1 to monitor the GATE1 voltage with the
0
ALARM comparator in windowing mode. Set to 0 to monitor the GATE1 voltage with the
ALARM comparator in hysteresis mode.
TALARM1
D3
Channel 1 temperature ALARM bit. Set to 1 to enable the alarm functionality for
0
channel 1 temperature measurements. Set to 0 to disable the alarm functionality for
channel 1 temperature measurements.
TWIN1
D2
Channel 1 temperature windowing bit. Set to 1 to monitor the channel 1 temperature
0
with the ALARM comparator in windowing mode. Set to 0 to monitor the channel 1
temperature with the ALARM comparator in hysteresis mode.
IALARM1
D1
Channel 1 sense voltage ALARM bit. Set to 1 to enable the alarm functionality for
0
channel 1 sense voltage measurements. Set to 0 to disable the alarm functionality for
channel 1 sense voltage measurements.
IWIN1
D0
Channel 1 sense voltage windowing bit. Set to 1 to monitor the channel 1 sense
0
voltage with the ALARM comparator in windowing mode. Set to 0 to monitor the
channel 1 sense voltage with the ALARM comparator in hysteresis mode.
42 ______________________________________________________________________________________