MAX11166 Datasheet, PDF (22/33 Pages) Maxim Integrated Products – 16-Bit, 500ksps/250ksps, ±5V SAR ADCs with Internal Reference in TDFN
MAX11166/MAX11167
16-Bit, 500ksps/250ksps, ±5V SAR ADCs
with Internal Reference in TDFN
CNVST
SCLK
DIN
tSSCKCNF
0
tSDINSCK
tHSCKCNF
123456701234567
tHDINSCK
B7 B6 B5 B4 B3 B2 B1 B0 B7 B6 B5 B4 B3 B2 B1 B0
DATA LOADED TO PART B
SHIFTED THROUGH PART A
DATA LOADED TO PART A
Figure 5. Input Configuration Timing in Daisy-Chain Mode
Configuring in Daisy-Chain Mode
Figure 5 details the configuration register load process
when the MAX11166/MAX11167 are connected in a
daisy-chain configuration (see Figure 12 and Figure 14
for hardware connections). The load process is enabled
on the falling edge of CNVST when SCLK is held high.
In daisy-chain mode, the input configuration registers are
chained together through DOUT to DIN. Device A’s DOUT
will drive device B’s DIN. The input configuration register
is an 8-bit, first-in first-out shift register. The configuration
data is clocked in N times through 8 O N falling SCLK
edges. After the MAX11166/MAX11167 ADCs in the chain
are loaded with the configuration byte, pull CNVST high
to complete the configuration register loading process.
Figure 5 illustrates a configuration sequence for loading
two devices in a chain.
Data loaded into the configuration register alters the state
of the MAX11166/MAX11167 on the next conversion cycle
after the register is loaded. However, powering up the inter-
nal reference buffer or stabilizing the REFIO pin voltage
will take several milliseconds to settle to 16-bit accuracy.
Shutdown Mode
The SHDN bit in the configuration register forces the
MAX11166/MAX11167 into and out of shutdown. Set
SHDN to 0 for normal operation. Set SHDN to 1 to shut
down all internal circuitry and reset all registers to their
default state.
Output Interface
The MAX11166/MAX11167 can be programmed into one
of four output modes; CS modes with and without busy
indicator and daisy-chain modes with and without busy
indicator. When operating without busy indication, the
user must externally timeout the maximum ADC conver-
sion time before commencing readback. When operating
in one of the two busy indication modes, the user can
connect the DOUT output of the MAX11166/MAX11167 to
an interrupt input on the digital host and use this interrupt
to trigger the output data read.
Regardless of the output interface mode used, digital
activity should be limited to the first half of the conversion
phase. Having SCLK or DIN transitions near the sampling
instance can also corrupt the input sample accuracy.
Therefore, keep the digital inputs quiet for approximately
25ns before and 10ns after the rising edge of CNVST.
These times are denoted as tSQ and tHQ in all subse-
quent timing diagrams.
In all interface modes, the data on DOUT is valid on
both SCLK edges. However, the input setup time into
the receiving digital host will be maximized when data is
clocked into that digital host on the falling SCLK edge.
Doing so will allow for higher data transfer rates between
the MAX11166/MAX11167 and the digital host and conse-
quently higher converter throughput.