8.7.2 E3x for Steam Service
DESIGN TYPE
E 3 Standard Construction Electronic Modulevel
MOUNTING AND CHAMBER MATERIALS
Flanged top Œ
Cage side/bottom
steel 316 SS steel 316 SS 
A
B
C
D
Cage side/side
steel 316 SS 
E
F
ΠAdjustable 8-foot hanger cable, part number 32-3110-001, required when
distance from flange face to top of displacer must be greater than 7.31".
 Bolting material is alloy steel.
SPECIFIC GRAVITY AND PROCESS TEMPERATURE
Integral or Remote Remote Integral or Remote Remote Transmitter Mounting
1&4 2&5
5
2&5 3&6
6 Use with Mounting/Temp. codes (9th Digit)
+300° F
(+150° C
+400° F
(+200° C)
+400° F
(+200° C)
+450° F
(+230° C)
+500° F
(+260° C)
+500° F
(+260° C)
maximum process temperature
K
B
K
N
E
N 0.55 - 1.09 specific gravity (all pressures)
PROCESS CONNECTION SIZE & TYPE
External Cage
11⁄2"
2"
A
E
R
F
P
Q
Top Mount
3"
4"
6"
n/a n/a n/a
n/a n/a n/a
G
H
K
Type
NPT
SW
Flange
CHAMBER PRESSURE CLASS
ANSI Flange rating
150# RF
3
300# RF
4
600# RF
5
900# RF
6
1500# RF 2500# RF Ž
7
8
Ž Pressure rating limited by enclosing tube to 5150 psi @ 100° F (355 bar @ 38° C)
LEVEL RANGE
All Pressures
14
32
48
356 813 1219
A
B
C
60
1524
D
72
1829
E
600# or below
84
96 108
2134 2438 2743
F
G
H
120
3048
I
Inches
mm
Code
TRANSMITTER – ELECTRONICS (see opposite page)
E3
56
F
48-640 E3 Modulevel Displacer Level Transmitter - FOUNDATION fieldbus™