8.4.3 ATEX (European Directive for Explosion Protection
Agency
ATEX
Model
XEXX-XXXX, EXX-XXXX
with transmitter codes
x1E, x1F, x1G, x1H
x2E, x2F, x2G, x2H
x3E, x3F, x3G, x3H
XEXX-XXXX, EXX-XXXX
with transmitter codes
x1A, x1B, x1C, x1D
x2A, x2B, x2C, x2D
x3A, x3B, x3C, x3D
XEXX-XXXX, EXX-XXXX
with transmitter codes
x1A, x1B, x1C, x1D
x2A, x2B, x2C, x2D
x3A, x3B, x3C, x3D
IEC
XEXX-XXXX, EXX-XXXX x1E, x1F, x1G, x1H
with transmitter codes
x2E, x2F, x2G, x2H
x3E, x3F, x3G, x3H
XEXX-XXXX, EXX-XXXX
with transmitter codes
x1A, x1B, x1C, x1D
x2A, x2B, x2C, x2D
x3A, x3B, x3C, x3D
Approval/Standards
Flameproof
ATEX Ex II 1/2 G Ex d IIC T6
EN 60079-0
EN 60079-1
EN 60079-26
94/9/EC
Intrinsically Safe 
ATEX Ex II 1 G Ex ia IIC T4
EN 60079-0
EN 60079-11
EN 60079-26
EN 60079-27
94/9/EC
Non-Sparking
ATEX Ex II 3 G Ex ic II T6
EN 60079-0
EN 60079-11
94/9/EC
Flameproof
IECEx Ex d IIC T6 Ga/Gb
IEC 60079-0
IEC 60079-1
IEC 60079-26
Intrinsically Safe 
IECEx Ex ia IIC T4 Ga
IEC 60079-0
IEC 60079-11
IEC 60079-26
IEC 60079-27
These units have been tested to
EN 61326 and are in compliance with
the EMC Directive 2004/108/EC.
ΠEntity parameters for intrinsically safe installation (FM & CSA):
non-FISCO
Vmax = 28.6 V
I max = 140 mA
Pmax = 1 W
Ci = 5.5 nF
Li = 9.4 µH
for FISCO Intrinsically Safe
Vmax = 17.5 V
I max = 500 mA
Pmax = 5.5 W
Ci ≤ 5 nF
Li ≤ 10 µH
 Entity parameters for intrinsically safe installation (ATEX/IEC):
non-FISCO
Ui = 28.4 V
I max = 94 mA
Pmax = 0.67 W
Ci = 2.2 nF
Li = 3 µH
for FISCO Intrinsically Safe
Ui = 17.5 V
I max = 380 mA
Pmax = 5.32 W
Ci = 0.705 nF
Li = 3 µH
Ž On remote electronics housing only, seal is required within 18
inches.
48-640 E3 Modulevel Displacer Level Transmitter - FOUNDATION fieldbus™