Process Conditions
Process temperature range Œ
Process pressure range
Environment
Electronics Operating Temperature
Display Function Operating Temperature
Storage Temperature
Humidity
Electromagnetic Compatibility
Shock Class
Vibration Class
Altitude
Pollution Degree
Steam applications:
-20° to +500° F (-29° to +260° C)
Non-steam applications:
-20° to +600° F (-29° to +315° C) 
5150 psig @ +100° F
(355 bar @ +38° C)
-40 to +176° F (-40 to +80° C)
-5 to +160° F (-20 to +70° C)
-50 to +185° F (-40 to +85° C)
0-99%, non-condensing
Meets CE Requirements: EN 61326
ANSI/ISA-S71.03 Class SA1 Ž
ANSI/ISA-S71.03 Class VC2 Ž
≤2000 m
2
8.6.2 Performance - Level
Linearity
Repeatability
Ambient temperature effect
Operating Temp. range:
LCD Temp. Range:
Hysteresis
Response Time
Warm-up Time
±0.50% of full span
±0.05% of full span
Maximum zero shift is 0.017%/°F over ambient temperature range
-40° to +176° F (-40° to +80° C)
-5° to +160° F (-20° to +70° C)
±0.05% of full span
<1 second
<5 seconds
8.6.3 Performance - Interface Level & Density
Linearity
Repeatability
Ambient temperature effect
±0.70% of full span
±0.10% of full span
Maximum zero shift is 0.017%/°F over ambient temperature range
ΠMaximum process temperatures are based on ambient temperatures less
than or equal to +120° F (+49° C). Higher ambient temperatures require
reduced process temperatures.
 Consult factory for low temperature applications down to -330° F (-200° C).
Ž With aluminum housing only. Does not apply to models with 316 SS
transmitter housings.
48-640 E3 Modulevel Displacer Level Transmitter - FOUNDATION fieldbus™
51