5.1 Measurement Type: Level Only (cont.)
Display
15
Run Time
xxxx.x h
16
History
Reset
17
MeasType
(select)
18
Model
(select)
19
SpringSG
(select)
20
SprgRate
x.x
21
SprgMatl
Password Action
None
Diagnostic Display showing
elapsed time since power on
or History Reset
SuperUser Press and select Yes to
clear history
Select type of measurement
SuperUser
Comment
Cleared to zero with History Reset
Select from Level, IfcLevel, or Density
Select the model number
SuperUser
Select spring SG range
SuperUser
Rate of spring in oz/in
SuperUser
Select from E3A, E3B, E3C, E3D, E3E, E3F, E31, E32, E33,
E34, E35, E36, Custom
Select 0.29–0.54, 0.55–1.09, 1.10–2.20, HighPres, or
Custom
Only selectable when custom selected for SpringSG.
Spring Material
SuperUser
Select Inc 600, Inc X750, 316 SS
22
TempLimt
xxx F
Enter maximum process
SuperUser
temperature
Enter maximum process temperature for which unit is
suitable
23
Length
xx.xx lu
Enter nominal displacer length Enter length of measuring range (7 to 240 inches)
SuperUser
24
Diameter
x.xxx in
Enter diameter of displacer
SuperUser
Enter outside diameter of displacer (0.5 to 5 inches)
25
Weight
xx.x oz
Enter weight of displacer
SuperUser
Enter weight of displacer (40 to 200 ounces)
26
CalSelct
(select)
27a
Factory Cal
Menu
27b User Cal Menu
28
AdjSnrLo
User
None
None
None
Select Factory or User
Calibration
Press to display the User
Calibration sub-menu
Press to display the User
Calibration sub-menu
Diagnostic Display
Selects Calibration Parameters used to calculate the
measured PV.
CalSelct = Factory
Submenu on page 33
CalSelct = User
Submenu on page 33
29
AdjSnrHi
None Diagnostic Display
30
Conv Fct
xxxx
None
Diagnostic Display
31
Scl Ofst
xxx
None
Diagnostic Display
32
LVDT%
xx.xx %
None
Diagnostic Display
33
Chan 0
None Diagnostic Display
34
Chan 1
None Diagnostic Display
35 NodeAddr SuperUser Diagnostic Display
Current node address of device
36 NSP Value SuperUser Diagnostic Display
37
ElecTemp
xxx C
None
Diagnostic Display
Present temperature in electronics compartment
38
Max Temp
xxx C
Diagnostic Display
SuperUser
Maximum electronics temperature recorded
39
Min Temp
xxx C
Diagnostic Display
SuperUser
Minimum electronics temperature recorded
32