LTC4015
Register Descriptions
SYMBOL
SUB R/W ACTIVE DESCRIPTION
ADDR
BITS
DEFAULT PAGE
VBAT_FILT
0x47 R
15:0
Digitally filtered two’s complement ADC measurement result for battery
voltage
73
ICHARGE_BSR
0x48 R
15:0
This 16-bit two's complement word is the value of IBAT (0x3D) used in
calculating BSR.
73
RESERVED
0x49
MEAS_SYS_VALID
0x4A R
0
Measurement valid bit, bit 0 is a 1 when the telemetry(ADC) system is
ready
73
Notes:
1. Some defaults are chemistry dependant. See the detailed register descriptions for more information.
2. Charger setting registers (sub-addresses 0x1A through 0x2D) are only writable if the CHEM pins are configured for a programmable chemistry option.
If the CHEM pins are configured for a fixed chemistry option, the charger setting registers are read only.