English
Language : 

N1055A Datasheet, PDF (17/19 Pages) Keysight Technologies – 35/50 GHz 2/4 Port TDR/TDT For the 86100D DCA-X Series Oscilloscope Mainframe
17 | Keysight | N1055A Remote Head Module 35/50 GHz 2/4 Port TDR/TDT - Data Sheet
Ordering Options
N1055A 35/50 GHz 2/4 port TDR/TDT remote head
Choose ONE option:
N1055A-32F
35 GHz, 2 channel, 2.92 mm, female
N1055A-32M
35 GHz, 2 channel, 2.92 mm, male
N1055A-34F
35 GHz, 4 channel, 2.92 mm, female
N1055A-34M
35 GHz, 4 channel, 2.92 mm, male
N1055A-52F
50 GHz, 2 channel, 1.85 mm, female
N1055A-52M
50 GHz, 2 channel, 1.85 mm, male
N1055A-54F
50 GHz, 4 channel, 1.85 mm, female
N1055A-54M
50 GHz, 4 channel, 1.85 mm, male
N1055A-FS1
Fast sampling
N1055A included accessories
N1027A-1CL
Cable management clips (6 at yellow, pink, blue, green)
N1027A-2CL
2 remote head clips
8710-1765
Torque wrench 8 lb-in, 5/16 in
85138-60002
1.85 mm load, male for each 50 GHz channel with female connector
85138-60001
1.85 mm load, female for each 50 GHz channel with male connector
00902-60003
3.5 mm load, male for each 35 GHz channel with female connector
00902-60004
3.5 mm load, female for each 35 GHz channel with male connector
N1055A optional accessories
N1027A-3MC
Storage case for N1055A module
N1027A-3AC
Accessory case for N1055A module
N1027A-1C1
Coaxial cable 1.85 mm, M/M, 67 GHz, 10 cm
Multiple module configurations require 86100D-ETR
86100D-ETR is required if more than one module in the DCA will be connected to the same DUT. for example if using two 2-channel modules to perform
TDR/TDT on one DUT.
Calibration kits
Electronic Calibration (ECal) modules
Note that for TDR applications, ECal modules must have no DC blocks and must be characterized to DC.
Most of the ECal modules in use today for VNA applications do not meet these requirements and are not
suitable for use with TDR. The following ECal modules are the only ECal modules available that meet the
requirements for TDR applications:
N4694A-HMM
ECal module, DC-67 GHz, 1.85 mm, male-male
N4694A-HFF
ECal module, DC-67 GHz, 1.85 mm, female-female
N4694A-HMF
ECal module, DC-67 GHz, 1.85 mm, male-female
Mechanical calibration kits supported by the 86100D
Note that some of the below mechanical calibration kits are no longer available. However, if you already have
one, you can use it with your 86100D TDR.
85033D
3.5 mm calibration kit, 30 kHz to 6 GHz
85033E
Standard mechanical calibration kit, DC to 9 GHz, 3.5 mm
85052B
Standard mechanical calibration kit, DC to 26.5 GHz, 3.5 mm
85052C
Precision mechanical calibration kit, DC to 26.5 GHz, 3.5 mm
85052D
Economy mechanical calibration kit, DC to 26.5 GHz, 3.5 mm
85056A
85056D
85056KE01 or KE02
85058B
85058E
N1024A or N1024B
Standard mechanical calibration kit, DC to 50 GHz, 2.4 mm
Economy mechanical calibration kit, DC to 50 GHz, 2.4 mm
Calibration kit, DC to 40 GHz, 2.92 mm
Standard mechanical calibration kit, DC to 67 GHz, 1.85 mm
Economy mechanical calibration kit, DC to 67 GHz, 1.85 mm
20 GHz SLT TDR calibration kit