14 | Keysight | E1963A W-CDMA Mobile Test Application - Technical Overview
HSPA code domain power
Code domain power accuracy: < ±0.4 dB for code power level > â25 dB
Relative code domain error (RCDE) accuracy: ⤠±0.5 dB for RCDE level > â20 dB
Relative code domain power accuracy (RCDPA):
ââ ⤠±0.2 dB for code power level from ⥠â10 to 0 dB
ââ ⤠±0.3 dB for code power level from ⥠â15, â10 dB
ââ ⤠±0.4 dB for code power level from ⥠â20, â15 dB
All measurements found in the waveform quality measurement are also available in the
code domain measurement; the specifications are the same in both measurements.
Measurement triggers: Immediate, protocol, external, auto, HS-DPCCH, and even frame
http://wireless.keysight.com/rfcomms/refdocs/wcdma/wcdma_meas_cod_dom_desc.html
Adjacent channel leakage ratio (ACLR)
Measurement method: Ratio of the filtered mean transmitted power to the filtered mean
power in an adjacent channel; both the transmitted and the adjacent channel powers are
measured with a filter that has a RRC response with roll-off a = 0.22 and a band width equal
to the chip rate
Input power level range: +5 to +28 dBm/3.84 MHz
Input frequency ranges: 698 to 1000 MHz, 1400 to 1500 MHz, 1700 to 2000 MHz, and 2480 to 2580 MHz
Measurement level ranging: Auto
Measurement accuracy: < ±0.8 dB (typically < ±0.5 dB), including the effects of the residual floor,
for measurements at â33 dBc at ±5 MHz offsets and â43 dBc at ±10 MHz offsets, and ±10 °C from
the calibration temperature
Residual ACLR floor: < â48 dBc for ±5 MHz offsets, < â58 dBc for ±10 MHz offsets
Measurement triggers: Auto, protocol, immediate, external, HS-DPCCH
Trigger alignment: Adjustable over subframes 0 to 5
Measurement interval: 1 timeslot
Measurement result: dBc relative to in-channel transmitted power
http://wireless.keysight.com/rfcomms/refdocs/wcdma/wcdma_meas_aclr_desc.html
|
▷ |