English
Language : 

ISL68137_16 Datasheet, PDF (51/53 Pages) Intersil Corporation – Digital Dual Output, 7-Phase Configurable PWM
ISL68137
AVSBUS STATUS (Eh)
Definition: Returns the device status. VDONE indicates that the VOUT setting target has been reached. OT Warn indicates that one or
more of the device’s temperature measurements has exceeded the over-temperature warning threshold set by the OT_WARN_LIMIT
PMBus command. The device sets the AVS_SDA line low to notify the host any time a bit in this register has been set.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Bit Field
Type: Read Only
Default Value: N/A
Units: N/A
COMMAND
Format
Bit Position
Access
Function
Default Value
15
R
VDONE
N/A
14
R
Not Used
0
AVSBUS STATUS (Eh)
Bit Field
13
R
Not Used
0
12
R
OT Warn
N/A
11:0
R
Not Used
0
AVSBUS VERSION (Fh)
Definition: Returns the version of the AVSBus specification to which the device is compliant. This device complies with Version 1.3.
Paged or Global: Global
Data Length in Bytes: 2
Data Format: Bit Field
Type: Read Only
Default Value: 00h
Units: N/A
Submit Document Feedback 51
FN8757.0
September 27, 2016