English
Language : 

ISL68137_16 Datasheet, PDF (45/53 Pages) Intersil Corporation – Digital Dual Output, 7-Phase Configurable PWM
ISL68137
READ_TEMPERATURE_3 (8Fh)
Definition: Returns the temperature reading from a remote diode connected to TMON1 when configured for diode sensing.
Paged or Global: Global
Data Length in Bytes: 2
Data Format: Direct
Type: Read Only
Default Value: N/A
Units: °C
Equation: READ_TEMPERATURE_3 = (Direct value)
COMMAND
READ_TEMPERATURE_3 (8Fh)
Format
Direct
Bit Position
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
Access
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Function
Two’s Complement Integer
READ_POUT (96h)
Definition: Returns the output power.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Direct
Type: Read Only
Default Value: N/A
Units: W
Equation: READ_POUT = (Direct value)
COMMAND
READ_POUT (96h)
Format
Direct
Bit Position
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
Access
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Function
Two’s Complement Integer
READ_PIN (97h)
Definition: Returns the input power.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Direct
Type: Read Only
Default Value: N/A
Units: W
Equation: READ_PIN = (Direct value)
COMMAND
READ_PIN (97h)
Format
Direct
Bit Position
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
Access
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Function
Two’s Complement Integer
Submit Document Feedback 45
FN8757.0
September 27, 2016