English
Language : 

ISL68137_16 Datasheet, PDF (26/53 Pages) Intersil Corporation – Digital Dual Output, 7-Phase Configurable PWM
ISL68137
PMBus Command Detail
PAGE (00h)
Definition: Selects Controller 0, Controller 1 or both Controllers 0 and 1 to receive commands. All commands following this command
will be received and acted on by the selected controller or controllers.
Data Length in Bytes: 1
Data Format: Bit Field
Type: R/W
Default Value: 00h
COMMAND
Format
Bit Position
Access
Function
Default Value
7
R/W
0
6
R/W
0
5
R/W
0
PAGE (00h)
Bit Field
4
3
R/W
R/W
See Following Table
0
0
2
R/W
0
1
R/W
0
0
R/W
0
BITS 7:4
0000
0000
1111
BITS 3:0
0000
0001
1111
PAGE
0
1
Both
OPERATION (01h)
Definition: Sets enable state when configured for PMBus enable. Sets the source of the target VOUT. The device always acts on faults
during margin. The table below reflects the valid settings for the device.
Paged or Global: Paged
Data Length in Bytes: 1
Data Format: Bit Field
Type: R/W
Default Value: 08h
COMMAND
Format
Bit Position
Access
Function
Default Value
7
R/W
0
6
R/W
0
5
R/W
0
OPERATION (01h)
Bit Field
4
3
R/W
R/W
See Following Table
0
1
2
R/W
0
1
R/W
0
0
R/W
0
BIT NUMBER
Bits 7:6
Bits 5:4
PURPOSE
Enable/Disable
VOUT Source
Bits 3:2
Bit 1
Margin Response
AVSBus Copy
Bit 0
Not Used
Submit Document Feedback 26
BIT VALUE
00
01
10
00
01
10
11
10
0
1
0
MEANING
Immediate Off (decay)
Soft-Off (Use TOFF_DELAY and TOFF_FALL)
On
VOUT_COMMAND
VOUT_MARGIN_LOW
VOUT_MARGIN_HIGH
AVSBus Target Rail Voltage
Act on Faults
VOUT_COMMAND remains unchanged
AVSBus Target Rail Voltage changes are copied
to VOUT_COMMAND
Not Used
FN8757.0
September 27, 2016