English
Language : 

ISL68137_16 Datasheet, PDF (33/53 Pages) Intersil Corporation – Digital Dual Output, 7-Phase Configurable PWM
ISL68137
VOUT_UV_FAULT_LIMIT (44h)
Definition: Sets the VOUT undervoltage fault threshold. This fault is masked during ramp or when disabled.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Direct
Type: R/W
Default Value: 0000h (0mV)
Units: mV
Equation: VOUT_UV_FAULT_LIMIT = (Direct value)
Range: 0V to VOUT_MAX
COMMAND
Format
Bit Position
Access
Function
Default Value
15
R/W
0
14
R/W
0
13
R/W
0
12
R/W
0
11
R/W
0
10
R/W
0
VOUT_UV_FAULT_LIMIT (44h)
Direct
9
8
7
6
R/W R/W R/W R/W
Two’s Complement Integer
0
0
0
0
5
R/W
0
4
R/W
0
3
R/W
0
2
R/W
0
1
R/W
0
0
R/W
0
OT_FAULT_LIMIT (4Fh)
Definition: Sets the power stage over-temperature fault limit.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Direct
Type: R/W
Default Value: 007Dh (+125°C)
Units: °C
Equation: OT_FAULT_LIMIT = (Direct value)
Range: 0°C to +2000°C
COMMAND
Format
Bit Position
Access
Function
Default Value
15
R/W
0
14
R/W
0
13
R/W
0
12
R/W
0
11
R/W
0
10
R/W
0
OT_FAULT_LIMIT (4Fh)
Direct
9
8
7
6
R/W R/W R/W R/W
Two’s Complement Integer
0
0
0
1
5
R/W
1
4
R/W
1
3
R/W
1
2
R/W
1
1
R/W
0
0
R/W
1
Submit Document Feedback 33
FN8757.0
September 27, 2016