English
Language : 

ISL68137_16 Datasheet, PDF (40/53 Pages) Intersil Corporation – Digital Dual Output, 7-Phase Configurable PWM
ISL68137
STATUS_VOUT (7Ah)
Definition: Returns a summary of output voltage faults.
Paged or Global: Paged
Data Length in Bytes: 1
Data Format: Bit Field
Type: Read Only
Default Value: N/A
COMMAND
Format
Bit Position
Access
Function
STATUS_VOUT (7Ah)
Bit Field
7
6
5
4
3
2
1
0
R
R
R
R
R
R
R
R
See Following Table
BIT NUMBER
7
6:5
4
3
2:0
STATUS BIT NAME
VOUT_OV_FAULT
Not Used
VOUT_UV_FAULT
VOUT_MAX Warning
Not Used
MEANING
Indicates an output overvoltage fault.
Not used
Indicates an output undervoltage fault.
Indicates an output voltage maximum warning.
Not used
STATUS_IOUT (7Bh)
Definition: Returns a summary of output current faults.
Paged or Global: Paged
Data Length in Bytes: 1
Data Format: Bit Field
Type: Read Only
Default Value: N/A
COMMAND
Format
Bit Position
Access
Function
STATUS_IOUT (7Bh)
Bit Field
7
6
5
4
3
2
1
0
R
R
R
R
R
R
R
R
See Following Table
BIT NUMBER
7
6
5:4
3
2:0
MEANING
An output overcurrent fault has occurred.
An output overcurrent and undervoltage fault has occurred.
Not used
A current share fault has occurred.
Not used
Submit Document Feedback 40