ISL68137
PMBus Command Summary (Continued)
CODE
COMMAND NAME
DESCRIPTION
8Eh READ_TEMPERATURE_2 Reports TMON0 temperature measurement
8Fh READ_TEMPERATURE_3 Reports TMON1 temperature measurement
96h READ_POUT
Reports output power
97h READ_PIN
Reports input power
98h PMBUS_REVISION
Reports specific events
ADh IC_DEVICE_ID
Reports device identification information
AEh IC_DEVICE_REV
Reports device revision information
E7h APPLY_SETTINGS
Instructs device to apply PMBus setting changes
F2h RESTORE_CONFIG
Allows selection of configurations from NVM
DATA DEFAULT
TYPE FORMAT VALUE
DEFAULT SETTING
Read Direct N/A
N/A
Read Direct N/A
N/A
Read Direct N/A
N/A
Read Direct N/A
N/A
Read Bit
33h
Revision 1.3
Read Bit
49D22700h ISL68137
Read Bit
N/A
N/A
Write BIT
01h
N/A
Write BIT
N/A
N/A
PMBus Use Guidelines
All commands can be read at any time
Always disable the outputs when writing commands that change device settings. Exceptions to this rule are commands intended to be
written while the device is enabled, for example, OPERATION.
PMBus Data Formats
Direct (D)
The Direct data format is a two byte two’s complement binary integer.
Bit Field (BIT)
Break down of Bit Field is provided in “PMBus Command Detail” on page 26.
Submit Document Feedback 25
FN8757.0
September 27, 2016