English
Language : 

X28HC256_15 Datasheet, PDF (4/19 Pages) Intersil Corporation – 256k, 32k x 8-Bit, 5V, Byte Alterable EEPROM
X28HC256
Absolute Maximum Ratings
Voltage on any Pin with Respect to VSS . . . . . . . . . . . . . . . . . . . . . 1V to +7V
DC Output Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10mA
Recommended Operating Conditions
Temperature Range
Commercial. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to +70°C
Industrial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -40°C to +85°C
Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5V ± 10%
Thermal Information
Temperature Under Bias
X28HC256. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -10°C to +85°C
X28HC256I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C
Pb-free Reflow Profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . see TB493
*Pb-free PDIPs can be used for through hole wave solder processing only.
They are not intended for use in Reflow solder processing applications.
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product
reliability and result in failures not covered by warranty.
DC Electrical Specifications Across recommended operating conditions, unless otherwise specified.
LIMITS
PARAMETER
SYMBOL
TEST CONDITIONS
MIN
TYP
(Note 7) (Note 5)
VCC Active Current
ICC
CE = OE = VIL, WE = VIH, All I/O’s = open,
30
(TTL Inputs)
address inputs = 0.4V/2.4V levels at f = 10MHz
VCC Standby Current
ISB1
CE = VIH, OE = VIL, All I/O’s = open, other inputs = VIH
1
(TTL Inputs)
VCC Standby Current
ISB2
CE = VCC - 0.3V, OE = GND, All I/Os = open, other
200
(CMOS Inputs)
inputs = VCC - 0.3V
Input Leakage Current
ILI
VIN = VSS to VCC
Output Leakage Current
ILO
VOUT = VSS to VCC, CE = VIH
Input Low Voltage
VlL (Note 6)
-1
Input High Voltage
VIH (Note 6)
2
Output Low Voltage
VOL
IOL = 6mA
Output High Voltage
VOH
IOH = -4mA
2.4
NOTES:
5. Typical values are for TA = +25°C and nominal supply voltage.
6. VIL minimum and VIH maximum are for reference only and are not tested.
7. Compliance to datasheet limits is assured by one or more methods: production test, characterization and/or design.
MAX
(Note 7)
60
2
500
10
10
0.8
VCC + 1
0.4
UNIT
mA
mA
µA
µA
µA
V
V
V
V
Power-up Timing
PARAMETER
SYMBOL
MAX
Power-up to Read
tPUR, (Note 8)
100
Power-up to Write
tPUW, (Note 8)
5
NOTE:
8. This parameter is periodically sampled and not 100% tested.
UNIT
µs
ms
Capacitance TA = +25°C, f = 1MHz, VCC = 5V.
SYMBOL
TEST
CI/O (Note 8)
CIN (Note 8)
Input/output capacitance
Input capacitance
Endurance and Data Retention
Endurance
Data retention
PARAMETER
CONDITIONS
VI/O = 0V
VIN = 0V
MAX
10
6
MIN
MAX
100,000
100
UNIT
pF
pF
UNIT
Cycles
Years
Submit Document Feedback
4
FN8108.5
August 27, 2015