ABSOLUTE MAXIMUM RATINGS
Temperature under bias .................... -65°C to +135°C
Storage temperature ......................... -65°C to +150°C
Voltage on any pin with
respect to VSS ...................................... -1.0V to +7V
D.C. output current ............................................... 5mA
Lead temperature (soldering, 10s) .................... 300°C
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Min.
0°C
-40°C
Max.
70°C
+85°C
COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only; functional operation of the
device (at these or any other conditions above those
listed in the operational sections of this specification) is
not implied. Exposure to absolute maximum rating con-
ditions for extended periods may affect device reliability.
Version
X40030, X40031
X40034, X40035
Chip Supply
Voltage
2.7V to 5.5V
2.7V to 5.5V
*See Ordering Info
Moitored*
Voltages
1.7V to 5.5V
1.0V to 5.5V
D.C. OPERATING CHARACTERISTICS
(Over the recommended operating conditions unless otherwise specified)
Symbol
ICC1(1)
ICC2(1)
Parameter
Active Supply Current (VCC) Read
Active Supply Current (VCC) Write
ISB1(1) Standby Current (VCC) AC (WDT off)
ISB2(2) Standby Current (VCC) DC (WDT on)
ILI
Input Leakage Current (SCL, MR, WP)
ILO Output Leakage Current (SDA, V2FAIL,
V3FAIL, WDO, RESET)
VIL(3)
VIH(3)
VHYS(6)
VOL
Input LOW Voltage (SDA, SCL, MR, WP)
Input HIGH Voltage (SDA, SCL, MR, WP)
Schmitt Trigger Input Hysteresis
• Fixed input level
• VCC related level
Output LOW Voltage (SDA, RESET/RE-
SET, LOWLINE, V2FAIL, V3FAIL, WDO)
VOH Output (RESET, LOWLINE) HIGH Volt-
age
VCC Supply
VTRIP1(5) VCC Trip Point Voltage Range
Second Supply Monitor
IV2 V2MON Current
Min.
-0.5
VCC x 0.7
0.2
.05 x VCC
VCC – 0.8
VCC – 0.4
2.0
4.55
4.35
2.85
Typ.(4)
6
25
4.6
4.4
2.9
Max.
1.5
3.0
10
30
10
10
VCC x 0.3
VCC + 0.5
0.4
4.75
4.65
4.45
2.95
15
Unit
mA
mA
µA
µA
µA
µA
V
V
V
V
V
V
V
V
V
V
µA
Test Conditions
VIL = VCC x 0.1
VIH = VCC x 0.9,
fSCL = 400kHz
VIL = VCC x 0.1
VIH = VCC x 0.9
fSCL, fSDA = 400kHz
VSDA = VSCL = VCC
Others = GND or VCC
VIL = GND to VCC
VSDA = GND to VCC
Device is in Standby(2)
IOL = 3.0mA (2.7-5.5V)
IOL = 1.8mA (2.7-3.6V)
IOH = -1.0mA (2.7-5.5V)
IOH = -0.4mA (2.7-3.6V)
X40030, X40031-A,
X40034, X40035
X40030, X40031-B
X40030, X40031-C
16
FN8114.1
May 25, 2006