Register Listing (Continued)
ADDRESS REGISTER (DEFAULT VALUE) BIT(s) FUNCTION NAME
DESCRIPTION
0x17
ABLC™ Configuration (0x40)
0
ABLC™ disable
0: ABLC™ enabled (default)
1: ABLC™ disabled
1
Reserved
Set to 0.
3:2
ABLC™ pixel width Number of black pixels averaged every line for ABLC™
function
00: 16 pixels [default]
01: 32 pixels
10: 64 pixels
11: 128 pixels
6:4
ABLC™ bandwidth ABLC™ Time constant (lines) = 2(5+[6:4])
000 = 32 lines
100 = 256 lines (default)
111 = 4096 lines
7
Reserved
Set to 0.
0x18
Output Format (0x00)
0
Bus Width
0: 24 bits: Data output on RP, GP, BP only; RS, GS, BS are all
driven low (default)
1: 48 bits: Data output on RP, GP, BP, RS, GS, BS
1
Interleaving
0: No interleaving: data changes on same edge of DATACLK
(48 bit mode only) (default)
1: Interleaved: Secondary databus data changes on
opposite edge of DATACLK from primary databus
2
Bus Swap
0: First data byte after trailing edge of HSOUT appears on
(48 bit mode only)
RP, GP, BP (default)
1: First data byte after trailing edge of HSOUT appears on
RS, GS, BS (primary and secondary busses are reversed)
3
Reserved
Set to 0.
4
422
0: Data is formatted as 4:4:4 (RGB, default)
(24 bit mode only) 1: Data is decimated to 4:2:2 (YUV), blue channel is driven
low
5
DATACLK
Polarity
0: HSOUT, VSOUT, and Pixel Data change on falling edge of
DATACLK (default)
1: HSOUT, VSOUT, and Pixel Data change on rising edge of
DATACLK
6
VSOUT Polarity
0: Active High (default)
1: Active Low
7
HSOUT Polarity
0: Active High (default)
1: Active Low
0x19
HSOUT Width (0x10)
7:0
HSOUT Width
HSOUT width, in pixels. Minimum value is 0x01 for 24 bit
modes, 0x02 for 48 bit modes.
0x1A
Output Signal Disable (0x00)
0
Three-state RP[7:0] 0 = Output byte enabled
1 = Output byte three-stated
1
Three-state RS[7:0] These bits override all other I/O settings
2
Three-state GP[7:0] Output data pins have 58kΩ pulldown resistors to GNDD.
3
Three-state GS[7:0]
4
Three-state BP[7:0]
5
Three-state BS[7:0]
6
Three-state
DATACLK
0 = DATACLK enabled
1 = DATACLK three-stated
7
Three-state
DATACLK
0 = DATACLK enabled
1 = DATACLK three-stated
14
FN8219.0