English
Language : 

ISL6398 Datasheet, PDF (10/57 Pages) Intersil Corporation – Programmable soft-start rate and DVID rate
ISL6398
Absolute Maximum Ratings
VCC, VR_RDY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +6V
ISENIN± . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .GND -0.3V to 27V
All Other Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .GND -0.3V to VCC + 0.3V
Recommended Operating Conditions
Supply Voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .+5V ±5%
EEPROM Write and Store Command Temperature . . . . . . -40°C to +85°C
Ambient Temperature
ISL6398HRTZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-10°C to +100°C
ISL6398IRTZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -40°C to +85°C
Thermal Information
Thermal Resistance (Notes 4, 5)
JA (°C/W) JC (°C/W)
40 Ld 5x5 TQFN Package . . . . . . . . . . . . . .
29
1
Maximum Junction Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . .+150°C
Maximum Storage Temperature Range . . . . . . . . . . . . . .-65°C to +150°C
Pb-Free Reflow Profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . see TB493
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product
reliability and result in failures not covered by warranty.
NOTES:
4. JA is measured in free air with the component mounted on a high effective thermal conductivity test board with “direct attach” features. See Tech
Brief TB379.
5. For JC, the “case temp” location is the center of the exposed metal pad on the package underside.
Electrical Specifications Recommended Operating Conditions, VCC = 5V, Unless Otherwise specified. Boldface limits apply across the
operating temperature range.
PARAMETER
TEST CONDITIONS
MIN
MAX
(Note 7) TYP (Note 7) UNITS
VCC SUPPLY CURRENT
Nominal Supply
Shutdown Supply
POWER-ON RESET AND ENABLE
VCC = 5VDC; EN_PWR = 5VDC; FSW = 400kHz
VCC = 5VDC; EN_PWR = 0VDC; FSW = 400kHz
-
35
45
mA
-
27
33
mA
VCC Rising POR Threshold
VCC Falling POR Threshold
EN_PWR_CFP High Level Turn-OFF Threshold
Externally Driven
4.22 4.35 4.55
V
4.00 4.10 4.22
V
3.5 3.6 3.7
V
EN_PWR_CFP High Level Turn-ON Threshold
Externally Driven
3.33 3.52 3.58
V
EN_PWR_CFP Latch-OFF Level
Internally Driven, 5mA Load
4.80
-
-
V
EN_PWR_CFP Internal Pull-Up Impedance
-
12
34

EN_PWR_CFP Rising Threshold
0.83 0.85 0.87
V
EN_PWR_CFP Falling Threshold
0.70 0.77 0.84
V
DAC (VID+OFFSET)
System Accuracy of Commercial Temperature
(TJ = 0°C to +70°C, Note 6, Closed-Loop)
DAC = 1.5V to 3.04 V
DAC = 0.8V to 1.49V
DAC = 0.25V to 0.795V
-0.5
-
0.5 %VID
-5
-
5
mV
-8
-
8
mV
System Accuracy of ISL6398HRTZ
(TJ = -10°C to +100°C, Note 6, Closed-Loop)
DAC = 1.5V to 3.04 V
DAC = 0.8V to 1.49V
DAC = 0.25V to 0.795V
-0.55
-
0.55 %VID
-7
-
7
mV
-9
-
9
mV
System Accuracy of ISL6398IRTZ
(TJ = -40°C to +85°C, Note 6, Closed-Loop)
DAC = 1.5V to 3.04 V
DAC = 0.8V to 1.49V
DAC = 0.25V to 0.795V
-0.6
-
0.6 %VID
-10
-
10
mV
-10
-
10
mV
Submit Document Feedback 10
FN8575.1