English
Language : 

TLE8110EE_13 Datasheet, PDF (71/74 Pages) Infineon Technologies AG – Overvoltage, Overtemperature, ESD -Protection
TLE 8110 EE
Smart Multichannel Switch
Control of the device
11
10
9
8
7
6
5
4
3
2
1
0
RCP
DBT2
DBT1
0
0
0
0
0
0
DCC10 DCC9 DCC18
Field
Bits
RCP
11
DBT2
10
DBT1
9
DEVS[7:5] 7:5
DEVS[4:3] 4:3
DCCx
2:0
Type
R/W
R/W
R/W
R/W
R/W
Description
RCP - Reverse Current Protection
1: reverse current comp is enabled (valid for all Channels)
0: disabled
default: RCP = 0
DBT2,1 - Diagnosis Blind Time Channel 7 to 10
0,0 standard Filter Time of typ. 150µs
1,0 standard Filter Time of typ. 150µs
0,1 OFF-state diagnosis Blind Time of typ. 2.5ms
1,1 OFF-state diagnosis Blind Time of typ. 5ms
Reserved, must be set to 0
default: 0
not used. set to ’0’
DCCx - Diagnosis Current Control
DCC18 switching ON/OFF diagnosis current of CH1-8
DCC9 switching ON/OFF diagnosis current of CH9
DCC10 switching ON/OFF diagnosis current of CH10
0 OFF-State Diagnosis (Detection of open load and short to GND)
of CHx is switched OFF. ON state diagnosis (over current and
over temperature detection) is still active.
Diagnosis Current is switched OFF.
1 OFF-State (Detection of open load and short to GND) and ON-
State (over current and over temperature detection) Diagnosis
of CHx switched ON,
Diagnosis Current is switched ON
default DCC = 1
Data Sheet
71
Rev. 1.4, 2013-07-02