English
Language : 

TLE8110EE_13 Datasheet, PDF (58/74 Pages) Infineon Technologies AG – Overvoltage, Overtemperature, ESD -Protection
TLE 8110 EE
Smart Multichannel Switch
Control of the device
S_SO
SPI_Serial Output
CS 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
PAR 0
0
0
0
0
0
0 SDS8 SDS7 SDS6 SDS5 SDS4 SDS3 SDS2 SDS1
Field
-
-
-
-
-
-
-
-
-
Bits
7:0
0
1
2
3
4
5
6
7
Type
-
-
-
-
-
-
-
-
-
Description
SDS - Short Diagnosis and Device Status
SDS1 - Diagnosis Error in Channel 1 to 6
0 normal operation
1 diagnosis failure
SDS2 - Diagnosis Error in Channel 7 to 10
0 normal operation
1 diagnosis failure
SDS3 - Under Voltage on VCC (Digital Supply Voltage)
see Figure 36
SDS4 - Under Voltage on VDD (Analogue Supply Voltage)
see Figure 36
SDS5 - Modulo Counter Error
0 normal operation
1 Previous Modulo Counter Error
SDS6 - Previous Communication Error - Encoded Command Ignored
0 normal operation
1 Previous Communication Error - Encoded Command Ignored
SDS7 - not used = ’0’
always ’0’
SDS8 - not used = ’0’
always ’0’