TLE8262-2E Datasheet, PDF (70/94 Pages) Infineon Technologies AG – Universal System Basis Chip | |||
|
◁ |
TLE8262-2E
Limp Home
13.6
Electrical Characteristics
VS = 5.5 V to 28 V; Tj = -40 °C to +150 °C; SBC Normal Mode; all voltages with respect to ground; positive current
defined flowing into pin unless otherwise specified.
Pos. Parameter
Symbol Limit Values
Unit Test Condition
Min. Typ. Max.
Limp Home;
13.6.1 Watchdog edge count
nLH
â
1
difference to set Limp
Home activated
2
â
â
With SPI set.
Default Setting
13.6.2 Limp Home low output
voltage (active)
VLHLO
â
0.2
0.4
V
ILH = 1mA
13.6.3
13.6.4
13.6.5
Limp Home high output
current (inactive)
INIT Time-out
Vcc1µC under voltage
Time-out
ILHHI
0
tINITTO
â
tVcc1UVTO 900
â
256
1024
2
µA
â
ms
1150 ms
VLH = 28V
1)
13.6.6 Vs threshold for Vcc1µC
VSthUV1 5.3
â
under voltage Time-out
(Vs needs to be above, to VSthUV2 4.3
â
activate Vcc1µC under
voltage Time-out)
VSthUV3 4.0
â
6.3
V
VRT1 default setting
5.3
V
VRT2 SPI option
5.0
V
VRT3 SPI option
13.6.7 Threshold for Limp Home VLHUV 4.5
â
minimum Vs
5.5
V
â
13.6.8 Limp Home Vs voltage
hysteresis
VLHUVhys â
0.2
â
V
â
LH _SI;
13.6.9 Limp Home side indicator fLHSI
frequency
1.125 1.25
1,375 Hz â
13.6.10 Limp Home side indicator dSI
â
duty cycle
50
â
%
â
LH_PL/Test
13.6.11 HIGH Level Input Voltage VTest,HI â
â
Threshold
3
V
â
13.6.12 Input Hysteresis
VTest,hys 100
300
13.6.13 LOW Level Input Voltage VTest,LO 1
â
Threshold
700 mV â
â
V
â
13.6.14 Pull-up Resistor
RTest
20
40
80
kâ¦
VLH_PL/Test = 0V
SBC Init Mode
13.6.15 Limp Home pulsed light fLH_PL 90
frequency
100
110 Hz â
13.6.16 Limp Home pulsed light dPL
-
duty cycle
1) Not subject to production test, specified by design.
20
-
%
â
Data Sheet
70
Rev. 1.0, 2009-05-26
|
▷ |