Bits
SWRST_BSTUV 14
UVLORST
13
STATE
12:11
TER
10
EOMON
9
EOMFS
8
EOCAL
7
VINOVLO
6
OUTOV
5
IVCCUVLO
4
Type
r
r
r
r
r
r
r
r
r
r
Description
SWRST OR VBSTx-VSWNx_UVth Monitor
0B , no SWRST or undervoltage on the Gate Drivers occured
1B , there was at least one SWRST since last readout OR an
undervoltage condition at the gate drivers is occurring
VDD OR VEN/INUVLO Undervoltage Monitor
0B , there was no VDD OR VEN/INUVLO undervoltage since last readout
1B , there was at least one VDD undervoltage OR VEN/INUVLO
undervoltage condition since last readout
Operative State Monitor
00B , (reserved)
01B , Limp Home Mode
10B , Active Mode
11B , Idle Mode
Transmission Error
0B , Previous transmission was successful
(modulo 16 + n*8 clocks received, where n = 0, 1, 2...)
1B , Previous transmission failed or first transmission after reset
End of LED/Input Current Monitor Routine Bit
0B , Current monitoring routine not completed, not successfully
performed or never run.
1B , Current Monitor routine successfully performed (is reset to 0B
when SOMON is set to 1B)
End of MFS Routine Bit
0B , MFS routine not completed, not successfully performed or
never run.
1B , MFS routine successfully performed (is reset to 0B when
SOMOFS is set to 1B)
End of Calibration Routine
0B , Calibration routine not completed, not successfully performed
or never run.
1B , Calibration routine successfully performed (is reset to 0B when
SOCAL is set to 1B)
VINOVLO Voltage Monitor
0B , VINOVLO below VINOVLOth threshold since last readout
1B , There was at least one VINOVLO overvoltage condition since last
readout
Output overvoltage Monitor
0B , Output overvoltage not detected since last readout
1B , Output overvoltage was detected since last readout
IVCC or IVCC_EXT Undervoltage Lockout Monitor
0B , IVCC and IVCC_EXT above VIVCC_RTH,d or VIVCC_EXT_RTH,d
threshold since last readout
1B , Undervoltage on IVCC or IVCC_EXT occurred since last
readout