Table 4-2 Operating Condition Parameters
Parameter
Symbol
Limit Values
Unit Notes
Min.
Max.
Digital supply voltage for VDDI
the core
Digital supply voltage for VDDP
IO pads
Supply Voltage Difference ∆VDD
Digital ground voltage
VSS
Overload current
IOV
Overload current coupling KOVD
factor for digital I/O pins7)
Absolute sum of overload Σ|IOV|
currents
2.35
4.4
-0.5
0
-5
–
–
–
2.7
V Active mode,
fCPU
=
f 1)
CPUmax
5.5
V Active mode2)3)
–
V
V
5
mA
5.0 × 10-3 –
1.0 × 10-2 –
50
mA
VDDP - VDDI4)
Reference voltage
Per IO pin5)6)
IOV > 0
IOV < 0
6)
External Load
Capacitance
CL
–
50
pF Pin drivers in
default mode8)
Ambient temperature
TA
0
70
-40
85
°C SAB-XC164…
°C SAF-XC164…
-40
125
°C SAK-XC164…
1) fCPUmax = 40 MHz for devices marked … 40F, fCPUmax = 20 MHz for devices marked … 20F.
2) External circuitry must guarantee low-level at the RSTIN pin at least until both power supply voltages have
reached the operating range.
3) The specified voltage range is allowed for operation. The range limits may be reached under extreme
operating conditions. However, specified parameters, such as leakage currents, refer to the standard
operating voltage range of VDDP = 4.75 V to 5.25 V.
4) This limitation must be fulfilled under all operating conditions including power-ramp-up, power-ramp-down,
and power-save modes.
5) Overload conditions occur if the standard operating conditions are exceeded, i.e. the voltage on any pin
exceeds the specified range: VOV > VDDP + 0.5 V (IOV > 0) or VOV < VSS - 0.5 V (IOV < 0). The absolute sum of
input overload currents on all pins may not exceed 50 mA. The supply voltages must remain within the
specified limits.
Proper operation is not guaranteed if overload conditions occur on functional pins such as XTAL1.
6) Not subject to production test - verified by design/characterization.
Data Sheet
45