English
Language : 

TC1767 Datasheet, PDF (31/126 Pages) Infineon Technologies AG – 32-Bit Single-Chip Microcontroller
TC1767
Introduction
• For further operating conditions see data sheet section “Flash Memory Parameters”.
Data Flash Features and Functions
• 64 Kbyte on-chip Flash, configured in two independent Flash banks of equal size.
• 64 bit read interface.
• Erase/program one bank while data read access from the other bank.
• Programming one bank while erasing the other bank using an automatic
suspend/resume function.
• Dynamic correction of single-bit errors during read access.
• Sector architecture:
– Two sectors of equal size.
– Each sector separately erasable.
• 128 byte pages to be written in one step.
• Operational control per command sequences (unlock sequences, same as those of
Program Flash) for protection against unintended operation.
• End-of-busy as well as error reporting with interrupt and bus error trap.
• Write state machine for automatic program and erase.
• Margin check for detection of problematic Flash bits.
• Endurance = 30000 (can be device dependent); i.e. 30000 program/erase cycles per
sector are allowed, with a retention of min. 5 years.
• Dedicated DFlash status information.
• Other characteristics: Same as Program Flash.
2.3.7 Data Access Overlay
The data overlay functionality provides the capability to redirect data accesses by the
TriCore to program memory (segments 8H and AH) called “target memory” to a different
memory called “overlay memory”.
Depending on the device the following overlay memories can be available:
• Overlay SRAM in the PMU.
• Emulation Memory1).
• External memory2).
This functionality makes it possible, for example, to modify the application’s test and
calibration parameters (which are typically stored in the program memory) during run
time of a program.
As the address translation is implemented in the DMI, it affects only data accesses
(reads and writes) of the TriCore. Instruction fetches by the TriCore or accesses by any
other master (including the debug interface) are not redirected.
1) Only available in Emulation Device “ED”.
2) Only available in Emulation Device with EBU.
Data Sheet
27
V1.3, 2009-09