English
Language : 

TC1767 Datasheet, PDF (108/126 Pages) Infineon Technologies AG – 32-Bit Single-Chip Microcontroller
TC1767
5.3.4 Power, Pad and Reset Timing
Electrical Parameters
Table 19 Power, Pad and Reset Timing Parameters
Parameter
Symbol
Min.
Values
Unit Note /
Typ. Max.
Test Conditi
on
Min. VDDP voltage to
ensure defined pad
states1)
Oscillator start-up time2)
Minimum PORST active
time after power supplies
are stable at operating
levels
VDDPPA CC 0.6
tOSCS CC –
tPOA SR 10
––
V–
– 10 ms –
––
ms –
ESR0 pulse width
tHD CC program –
–
mable3)5)
fSYS –
PORST rise time
Setup time to PORST
rising edge4)
tPOR
tPOS
SR –
SR 0
– 50 ms –
––
ns –
Hold time from PORST
rising edge
tPOH SR 100
––
ns TESTMODE
TRST
Setup time to ESR0 rising tHDS SR 0
edge
––
ns –
Hold time from ESR0
rising edge
Ports inactive after
PORST reset active6)7)
tHDH SR 16 ×
–
1/fSYS5)
tPIP CC –
–
–
ns HWCFG
150 ns –
Ports inactive after ESR0 tPI
reset active (and for all
logic)
CC –
– 8 × ns –
1/fSYS
Power on Reset Boot
Time8)
tBP CC –
– 2.5 ms –
Application Reset Boot
tB
CC 150
Time 9)10)
–
700 µs fCPU=133MHz
960 µs fCPU=80MHz
1) This parameter is valid under assumption that PORST signal is constantly at low level during the power-
up/power-down of the VDDP.
Data Sheet
104
V1.3, 2009-09