Final Data TLE 6262 G
2.3 Electrical Characteristics (cont’d)
9 V < VS < 16 V; ICC = -100 mA; normal mode; all outputs open; – 40 °C < Tj < 150 °C; CAN-
transceiver circuitry: – 40 °C < Tj < 125 °C; all voltages with respect to ground; positive current
defined flowing into pin; unless otherwise specified.
Parameter
Symbol Limit Values Unit Test Condition
min. typ. max.
CANL dominant output
voltage
VCANLd
–
1.0 1.4 V
TxD = 0 V;
ICANL = 40 mA
CANH output current
CANL output current
ICANH
ICANL
Voltage detection threshold Vdet(th)
for short-circuit to battery
voltage on CANH and CANL
-110 -80
-5 0
50 80
-5 0
6.5 7.3
-50 mA VCANH = 0 V;
TxD = 0 V
5
µA sleep mode;
VCANH = 12 V
110 mA VCANL = 5 V;
TxD = 0 V
5
µA sleep mode;
VCANL = 0 V;
VS = 0 V
8.0 V
normal operation
mode
CANH wake-up voltage
threshold
VWAKEH 1.2 1.9 2.7 V
–
CANL wake-up voltage
threshold
VWAKEL 2.2 3.1 3.9 V
–
CANH single-ended receiver VCANH
threshold
1.6 2.1 2.6 V
failure cases 3, 5 and
7
CANL single-ended receiver VCANL
threshold
2.4 3.0 3.4 V
failure case 6 and 6a
CANL leakage current
CANH leakage current
ICANLl
-5
0
5
µA VCC = 0 V, VS = 0 V,
VCANL = 13.5 V,
Tj < 85 °C
ICANHl
-5
0
5
µA VCC = 0 V;VS = 0 V;
VCANH = 5 V;
Tj < 85 °C
Termination Outputs RTL, RTH
RTL to VCC switch-on
resistance
RRTL
–
RTL to BAT switch series RoRTL 5
resistance
40
95
W
Io = – 10 mA;
15
30
kW VBAT-stand-by
24
version: 2.03 date: 2002-03-20