Final Data TLE 6262 G
2.3 Electrical Characteristics (cont’d)
9 V < VS < 16 V; ICC = -100 mA; normal mode; all outputs open; – 40 °C < Tj < 150 °C; CAN-
transceiver circuitry: – 40 °C < Tj < 125 °C; all voltages with respect to ground; positive current
defined flowing into pin; unless otherwise specified.
Parameter
Symbol Limit Values Unit Test Condition
min. typ. max.
Reset Generator; Pin RO
Reset threshold voltage
VRT
Reset low output voltage
VRO
Reset high output voltage VRO
Reset pull up current
IRO
Reset reaction time
tRR
Reset delay time (16 cyl.) tRD
4.0 4.3 4.65 V
0.2 0.4 V
4.0
VCC+ V
0.1
IRO = 1mA
(VCC ³ VRT) or
VCC ³ 1V
(IRO = 200 µA)
20 150 500 mA VRO = 0V
1
3
10
µs
VCC < VRT to
RO = L
6.1 8.1 10.2 ms ROSC = 453kW
3 V Supervisor; (bit 7 of SPI diagnosis word)
Supervisor threshold voltage VST
Supervisor reaction time
tSR
2.3 2.7 3.1 V
2
8
20
µs
VCC < VST to
diagnosis bit 7 = L
Watchdog Generator
Watchdog trigger time
tWD
7.6
Closed window time (12 cyl.) tCW
4.6
Open window time (20 cyl.) tOW
7.7
Watchdog reset-puls time tWDR
1.5
(4 cyl.)
Watchdog activating current ICCWD 2
Watchdog activating current ICCWDhys
hysteresis
10 12.3 ms
6.1 7.6 ms
10.2 12.7 ms
2.0 2.6 ms
ROSC = 453kW
ROSC = 453kW
ROSC = 453kW
ROSC = 453kW
4
12
0.5
mA Tj < 85 °C; Watchdog
OFF when
ICC < ICCWD and SPI-
input bit 8 = H
mA
19
version: 2.03 date: 2002-03-20