English
Language : 

TLE6262G Datasheet, PDF (21/38 Pages) Infineon Technologies AG – Fault Tolerant CAN - LDO
Final Data TLE 6262 G
2.3 Electrical Characteristics (cont’d)
9 V < VS < 16 V; ICC = -100 mA; normal mode; all outputs open; – 40 °C < Tj < 150 °C; CAN-
transceiver circuitry: – 40 °C < Tj < 125 °C; all voltages with respect to ground; positive current
defined flowing into pin; unless otherwise specified.
Parameter
Symbol Limit Values Unit Test Condition
min. typ. max.
PWM Input to control OUTH1; Pin PWM (high active)
H-input voltage threshold
VIH
L-input voltage threshold
VIL
Hysteresis of input voltage VIHY
Pull down current
II
Input capacitance
CI
–
–
0.2 –
´Vcc
50 200
5
25
–
10
0.7 V
´VCC
–
V
500 mV
180 mA
15 pF
–
–
–
VI = 0.2 * VCC
0 V < VCC < 5.25 V
High Side Output OUTH2; (controlled by bit 2 of SPI input word)
Static Drain-Source
R – DSON H2
1.0 2.0 W
ON-Resistance;
IOUTH2 = -0.25 A
1.5 4.0 W
Active zener voltage
VOUTH2 -5.0 -3.0 -0.5 V
Clamp diode forward voltage VOUTH2
0.8 1
V
Leakage current
IOLH1
-100 -5 –
µA
Switch ON delay time
tdONH1
10 100 µs
Switch OFF delay time
tdOFFH1
20 100 µs
5.2 V £ VS £ 9 V
IOUTH2 = – 0.25 A
IOUTH2 = 0.25 A
VOUTH2 = 0 V
CSN high to OUTH2;
RL = 100 W
CSN high to OUTH2;
RL = 100 W
High Side Output OUTH3; (controlled by bit 3 and bit 4 of SPI input word)
Static Drain-Source
R – DSON H3
1.5 3.0 W
ON-Resistance;
IOUTH3 = -0.15 A
2.0 5.0 W
Active zener voltage
VOUTH3 -5.0 -3.0 -0.5 V
Clamp diode forward voltage VOUTH3
0.8 1
V
Leakage current
IOLH3
-100 -5 –
µA
5.2 V £ VS £ 9 V
IOUTH3 = – 0.15 A
IOUTH3 = 0.15 A
VOUTH3 = 0 V
21
version: 2.03 date: 2002-03-20