English
Language : 

90E32 Datasheet, PDF (63/71 Pages) Integrated Device Technology – Poly-Phase High-Performance Wide-Span Energy Metering IC
90E32
POLY-PHASE HIGH-PERFORMANCE WIDE-SPAN ENERGY METERING IC
7.2 METERING/ MEASUREMENT ACCURACY
7.2.1 METERING ACCURACY
Metering accuracy or energy accuracy is calculated with relative
error:
γ
=
Emea − Ereal
Ereal
×100%
Where Emea is the energy measured by the meter, Ereal is the actual
energy measured by a high accurate normative meter.
Table-14 Metering Accuracy for Different Energy within the Dynamic Range
Energy Type
Energy Pulse
ADC Range
When Gain=1
Metering Accuracynote 1
Active energy
CF1
(Per phase and all-phase-sum)
PF=1.0 120µV-600mV
PF=0.5L, 180µV-600mV
0.1%
PF=0.8C, 150µV-600mV
Reactive energy
CF2
(Per phase and all-phase-sum)
sinФ=1.0 120µV-600mV
sinФ=0.5L, 180µV-600mV
0.2%
sinФ=0.8C, 150µV-600mV
Apparent energy
CF2
(Per phase and arithmetic all-phase-sum)
600µV-600mVnote 2
0.2%
Fundamental active energy
CF3
(Per phase and all-phase-sum)
PF=1.0 120µV-600mV
PF=0.5L, 180µV-600mV
0.2%
PF=0.8C, 150µV-600mV
Harmonic active energy
CF4
(Per phase and all-phase-sum)
PF=1.0 120µV-600mV
PF=0.5L, 180µV-600mV
0.5%
PF=0.8C, 150µV-600mV
Note 1: All the parameters in this table is tested on IDT’s test platform.
Note 2: Apparent energy is tested using active energy with unity power factor since there’s no standard for apparent energy. Signal below 600 µV is not tested.
Electrical Specification
63
December 9, 2011