English
Language : 

7132SA100J Datasheet, PDF (4/16 Pages) Integrated Device Technology – HIGH SPEED 2K x 8 DUAL PORT STATIC RAM
IDT7132SA/LA and IDT 7142SA/LA
High Speed 2K x 8 Dual Port Static RAM
Military, Industrial and Commercial Temperature Ranges
DC Electrical Characteristics Over the Operating
Temperature and Supply Voltage Range(1,5,8) (VCC = 5.0V ± 10%)
7132X20(2)
7142X20(2)
Com'l Only
7132X25(7)
7142X25(7)
Com'l, Ind
& Military
7132X35
7142X35
Com'l &
Military
Symbol
Parameter
Test Condition
Version
Typ. Max. Typ. Max. Typ. Max. Unit
ICC
Dynamic Operating Current CEL = CER = VIL,
(Both Ports Active)
Outputs Disabled
f = fMAX(3)
COM'L SA 110
250
110
220
80
165 mA
LA 110
200
110
170
80
120
MIL &
SA
____
____
110
280
80
230
IND
LA
____
____
110
220
80
170
ISB1
Standby Current
(Both Ports - TTL
Level Inputs)
CEL = CER = VIH,
f = fMAX(3)
COM'L SA 30
65
30
65
25
65
mA
LA 30
45
30
45
25
45
MIL &
SA
____
____
30
80
25
80
IND
LA
____
____
30
60
25
60
ISB2
Standby Current
(One Port - TTL
Level Inputs)
CE"A" = VIL and CE"B" = VIH(6)
Active Port Outputs Disabled
f=fMAX(3)
COM'L SA 65
165
65
150
50
125 mA
LA 65
125
65
115
50
90
MIL &
SA
____
____
65
160
50
150
IND
LA
____
____
65
125
50
115
ISB3
Full Standby Current (Both CEL and CER > VCC -0.2V
COM'L SA 1.0
15
1.0
15
1.0
15
mA
Ports - All
VIN > VCC -0.2V or VIN < 0.2V, f = 0(4)
LA 0.2
5
0.2
5
0.2
4
CMOS Level Inputs)
MIL &
SA
____
____
1.0
30
1.0
30
IND
LA
____
____
0.2
10
0.2
10
ISB4
Full Standby Current
(One Port - All
CMOS Level Inputs)
CE"A" < 0.2V andCE"B" > VCC -0.2V(6)
COM'L SA 60
155
60
145
45
110 mA
VIN > VCC - 0.2V or VIN < 0.2V
LA 60
115
60
105
45
85
Active Port Outputs Disabled
f = fMAX(3)
MIL &
SA
____
____
60
155
45
145
IND
LA
____
____
60
115
45
105
7132X55
7142X55
Com'l &
Military
7132X100
7142X100
Com'l &
Military
2692 tbl 04a
Symbol
Parameter
Test Condition
Version
Typ. Max. Typ. Max. Unit
ICC
Dynamic Operating
Current
(Both Ports Active)
CEL = CER = VIL,
Outputs Disabled
f = fMAX(3)
COM'L SA 65
155
65
155 mA
LA 65
110
65
110
MIL &
SA 65
190
65
190
IND
LA 65
140
65
140
ISB1
Standby Current
(Both Ports - TTL
Level Inputs)
CEL = CER = VIH,
f = fMAX(3)
COM'L SA 20
65
20
55
mA
LA 20
35
20
35
MIL &
SA 20
65
20
65
IND
LA 20
45
20
45
ISB2
Standby Current
(One Port - TTL
Level Inputs)
CE"A" = VIL and CE"B" = VIH(6)
Active Port Outputs Disabled
f=fMAX(3)
COM'L SA 40
110
40
110 mA
LA 40
75
40
75
MIL &
SA 40
125
40
125
IND
LA 40
90
40
90
ISB3
Full Standby Current
(Both Ports - All
CMOS Level Inputs)
CEL and CER > VCC -0.2V
VIN > VCC -0.2V or VIN < 0.2V, f = 0(4)
COM'L SA 1.0
15
1.0
15
mA
LA 0.2
4
0.2
4
MIL &
SA 1.0
30
1.0
30
IND
LA 0.2
10
0.2
10
ISB4
Full Standby Current
(One Port - All
CMOS Level Inputs)
CE"A" < 0.2V and CE"B" > VCC -0.2V(6)
VIN > VCC - 0.2V or VIN < 0.2V
Active Port Outputs Disabled
f = fMAX(3)
COM'L SA 40
100
40
LA 40
70
40
95
mA
70
MIL &
SA 40
110
40
110
IND
LA 40
85
40
80
NOTES:
2692 tbl 04b
1. 'X' in part numbers indicates power rating (SA or LA).
2. PLCC Package only
3. At f = fMax, address and control lines (except Output Enable) are cycling at the maximum frequency read cycle of 1/tRC, and using “AC TEST CONDITIONS” of input levels
of GND to 3V.
4. f = 0 means no address or control lines change. Applies only to inputs at CMOS level standby.
5. Vcc = 5V, TA=+25°C for Typ and is not production tested. Vcc DC = 100mA (Typ)
6. Port "A" may be either left or right port. Port "B" is opposite from port "A".
7. Not available in DIP packages.
8. Industrial temperature: for specific speeds, packages and powers contact your sales office.
4