English
Language : 

IC-MU150 Datasheet, PDF (39/64 Pages) IC-Haus GmbH – MAGNETIC OFF-AXIS POSITION ENCODER - POLE WIDTH 1.50MM
iC-MU150 MAGNETIC OFF-AXIS
POSITION ENCODER - POLE WIDTH 1.50MM
Rev B1, Page 39/64
an error within 22.5° (in the Figure between 67.5° and
90°) can not be corrected. For SPO_0 the range of a
possible slope change is exemplary shown.
0°
22.5° 45° 67.5° 90° 112.5° 145° 167.5°180° 202.5°225° 247.5°270° 292.5°315° 337.5°3r6e0°lative to
M-N
slope used
in range
+ 1 period
- 1 period
tolerable
offset
error
SPO_BASE
SPO_0
SPO_1
error curve
resulting curve
spo_x curve
spo_x correction
range
NCHK_NON
Addr. 0x0D; bit 5
Code
Description
0
automatic period verification
1
no automatic period verification
Table 61: Automatic nonius period verification
The nonius data and incremental interface can be auto-
matically reset with ACRM_RES if the master amplitude
is too low. The incremental section is reset as soon
as the amplitude control unit indicates that the master
amplitude is too low (AM_MIN occurs, see Table 100).
The ABZ-interface shows position 0 as default. When
the master amplitude is again in its set range, a new
nonius calculation is carried out and the incremental
section is restarted.
ACRM_RES
Addr. 0x0D; bit 4
Code
Description
0
no automatic reset
1
automatic reset active
Figure 34: Nonius track offset calibration
Table 62: Automatic Reset triggered by AM_MIN
normal operation
Following the first nonius synchronization the number
of excessed periods is counted and output. Using
NCHK_NON the system can be configured to check the
internal period counter against the period given by the
code disc at regular intervals. Command NON_VER ex-
plicitly requests nonius verification. If an error is found
during verification of the nonius, bit NON_CTR is set in
status register STATUS1.
ACRM_RES? no
yes
AM_MIN
no
error set?
yes
reset incr. part
no
incr. part
in reset state?
yes
wait
20 ms
Figure 35 describes the principle of nonius synchroniza-
tion with verification, with φ representing the respective
digitized angle of the relevant track.
initial nonius calculation
jm - jn
SYNC BITS
jm
CORRECTION
MPC
12 Bit
nonius reset
multiturn reset
yes startup multiturn no
ok?
restart incr. part
jm
CNT_PERIOD
+
Figure 36: Automatic reset ACRM_RES
jabsolut
MSB
INTERNAL
LSB W ORD
Figure 35: Principle of nonius synchronization