English
Language : 

IC-MU150 Datasheet, PDF (30/64 Pages) IC-Haus GmbH – MAGNETIC OFF-AXIS POSITION ENCODER - POLE WIDTH 1.50MM
iC-MU150 MAGNETIC OFF-AXIS
POSITION ENCODER - POLE WIDTH 1.50MM
SSI interface
Rev B1, Page 30/64
ERR
out
cyle
Figure 17: Example of SSI line signals (MODEA=0x5/0x6) with optional unidirectional register communica-
tion
LSB
ERR WRN MSB
LSB
Zero bits
CRC
out
cycle
Figure 18: Example of extended SSI line signals (MODEA=0x7, ExtSSI)
MODEA
Code
0x4
0x5
0x6
0x7
Description
Standard SSI, no error-bit
Standard SSI, error-bit low active
Standard SSI, error-bit high active
extended SSI, data-package like BiSS-C
Table 44: MODEA: SSI
In standard SSI mode singleturn data and, optionally,
multiturn data, an error, and a stop zero can be transmit-
ted. In extended SSI mode (ExtSSI) the multiturn data
(optional), singleturn data, error, warning, and CRC can
be read out. All data is sent with the MSB first and is
equivalent to the data package that is output through
BiSS.
The SSI interface of iC-MU150 can handle sensor data
communication and unidirectional register communica-