iC-LNB 18-BIT OPTO ENCODER preliminary
WITH SPI AND SER/PAR INTERFACES
DESIGN REVIEW: Notes On Chip Functions
Rev A1, Page 34/35
iC-LNB X
No.
1
2
3
4
5
Function, Parameter/Code
FlexCount outputs low:
NOUTLO = 1
Permissible interpolator resolutions:
RESIPO = 0x0 (8 bit) or
RESIPO = 0x3 (deactivated)
Default value of address 0x11 is 0x50
LCMOD not available
LCTYP (address 0x06):
reset value is 0x30
Description and Application Notes
Due to potential malfunction this parameter must not be used.
Interpolator resolution 6/7 bit:
If the rotation alters its direction, incremental and parallel outputs may switch
wrong.
For configuration of iC-LNB first program address 0x11 to 0xA0, then follow
sequence in figure 4.
standard control active
For configuration of iC-LNB first program address 0x06 to 0x60, then follow
sequence in Figure 4.
Table 53: Notes on chip functions regarding iC-LNB chip release X
iC-LNB X1
No.
1
2
3
Function, Parameter/Code
Interpolation without angle hysteresis
(Elec. Char. No. 703)
LCMOD not available
LCTYP (address 0x06):
reset value is 0x30
Description and Application Notes
Use FlexCount (NENFLEX=0) with hysteresis of at least 1 LSB configured by
HYS.
standard control active
For configuration of iC-LNB first program address 0x06 to 0x60, then follow
sequence in Figure 4.
Table 54: Notes on chip functions regarding iC-LNB chip release X1
iC-LNB W1
No.
Function, Parameter/Code
1
LCTYP (address 0x06):
reset value is 0x30
Description and Application Notes
For configuration of iC-LNB first program address 0x06 to 0x60, then follow
sequence in Figure 4.
Table 55: Notes on chip functions regarding iC-LNB chip release W1
iC-Haus expressly reserves the right to change its products and/or specifications. An info letter gives details as to any amendments and additions made to the
relevant current specifications on our internet website www.ichaus.de/infoletter; this letter is generated automatically and shall be sent to registered users by
email.
Copying – even as an excerpt – is only permitted with iC-Haus’ approval in writing and precise reference to source.
iC-Haus does not warrant the accuracy, completeness or timeliness of the specification and does not assume liability for any errors or omissions in these
materials.
The data specified is intended solely for the purpose of product description. No representations or warranties, either express or implied, of merchantability, fitness
for a particular purpose or of any other nature are made hereunder with respect to information/specification or the products to which information refers and no
guarantee with respect to compliance to the intended use is given. In particular, this also applies to the stated possible applications or areas of applications of
the product.
iC-Haus conveys no patent, copyright, mask work right or other trade mark right to this product. iC-Haus assumes no liability for any patent and/or other trade
mark rights of a third party resulting from processing or handling of the product and/or any other use of the product.