English
Language : 

IC-MH_17 Datasheet, PDF (24/26 Pages) IC-Haus GmbH – 12-BIT ANGULAR HALL ENCODER
iC-MH
12-BIT ANGULAR HALL ENCODER
Rev C2, Page 24/26
A typical PCB layout may look like the one shown in The ROM content may be protected against further
figure 27.
changes by register CFGPROT.
CFGPROT
0
1
Addr. 0x05; bit 6
no protection
write/read protection
Table 33: Write/read protection of configuration
With CFGPROT = ’0’, the registers at the addresses
0x00 to 0x0F and 0x78 to 0x7F are readable and write-
able. The addresses 0x10 to 0x1F and 0x77 are read-
-only. With CFGPROT = ’1’, all registers except the
addresses 0x7B and 0x7C are write-protected; the ad-
dresses 0x77 to 0x7F are readable, while all others are
read-protected.
Figure 27: Example PCB layout showing low impedance
connection of capacitors to supply voltages
(VPA, VPD, VZAP) and common ground
DESIGN REVIEW: Notes on Chip Functions
iC-MH Y
No.
Function, Parameter/Code
Description and Application Hints
No further notes at time of printing.
Table 34: Notes on chip functions regarding iC-MH chip release Y.