English
Language : 

US10D10A00 Datasheet, PDF (92/94 Pages) Honeywell Solid State Electronics Center – Basic Switches
Basic Switches
Double-break
3MN Series
FEATURES
ɀ .080 inch minimum overtravel
ɀ Power load switching capability up to
15 amperes
ɀ Motor handling capacity of 1 horse-
power at 240 vac.
ɀ Long mechanical life of 10,000,000 cy-
cles—95% survival
ɀ Arc resistant plastic
ɀ More space between terminals to re-
duce possibility of shorting
ɀ #8 Terminal screws
ɀ UL recognized, CSA certified
GENERAL INFORMATION
3MN switches are for use with limit or con-
trol mechanisms on machine tools,
presses or other industrial equipment.
These switches provide easy gang
mounting.
The terminals of double-break switches
must be wired to identical voltage sourc-
es and the same polarity. The loads
should be on the same sides of the lines.
ELECTRICAL RATING
Circuitry
Electrical Data and
UL Codes
Two-circuit
double-break
V Motor Control
15 amps, 120, 240, 480 or 600 vac;
1/2 hp, 120 vac; 1 hp, 240 vac;
0.8 amp, 115 vdc; 0.4 amp,
230 vdc.
Dim. Dwg. Fig. 1
ORDER GUIDE
Characteristics: O.F. — Operating Force; R.F. — Release Force; P.T.
— Pretravel; O.T. – Overtravel; D.T. — Differential Travel; O.P. — Operating
Position.
Catalog
Listing
3MN1
3MN6
Description
For most
applications
Lower force
Electrical
Data and
UL Codes
15 Amps
V
15 Amps
V
O.F.
newtons
ounces
3,34-5,56
12-20
1,95-3,1
7-11
R.F.
min.
newtons
ounces
1,67
6
1,11
4
P.T.
max.
mm
inches
1,52
.060
1,52
.060
O.T.
min.
mm
inches
2,03
.080
2,03
.080
D.T.
mm
inches
0,38-0,63
.015-.025
0,38-0,63
.015-.025
O.P.* max.
mm
inches
2,16
.085
2,16
.085
* ±0,38 mm
±.015 in.
MOUNTING DIMENSIONS (For reference only)
Fig. 1
For application help: call 1-800-537-6945.
Honeywell Sensing and Control 73