US10D10A00 Datasheet, PDF (24/94 Pages) Honeywell Solid State Electronics Center – Basic Switches
Basic Switches
SX
Subminiature
AUXILIARY
ACTUATORS
Switches are not
included with
actuators.
Dim. Dwg. Fig. 7
ORDER GUIDE
Characteristics: O.F. – Operating Force; R.F. – Release Force; P.T. –
Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P. – Operating
Position; F.P. – Free Position.
*All characteristics are taken with actuator assembled on Catalog Listing 1SX1-T as shown.
Catalog
Listing
Description
Actuator
Length
‘‘A’’ O.F. max. R.F. min.
mm newtons newtons
inches ounces ounces
JX-20 Straight lever
18.3
0,28
0,04
.72
1
.14
approx.
JX-219 Straight lever
18,3
0,28
0,04
(For higher temp.) .72
1
.14
P.T.
mm
inches
—
—
O.T.
mm
inches
0,76
.030
approx.
0,76
.030
approx.
D.T. max.
mm
inches
0,76
.030
approx.
0,76
.030
approx.
O.P.††
mm
inches
10,8
.425
approx.
10,8
.425
approx.
F.P.
mm
inches
12,3
.485
approx.
12,3
.485
approx.
JX-25 Roller lever
16,5
0,42
0,04
—
0,51
0,76 14,9⍧1,14 168
.65
1.5
1.4
.020
.030 .585⍧.045 .660
max.
JX-220 Roller lever
16,5
0,42
0,04
—
0,51
0,76 14,9⍧1,14 16,8
Dim. Dwg. Fig. 8
(For higher temp.) .65
1.5
.14
.020
.030 .585⍧.045 .660
max.
JX-40 Straight leaf
9,4
1,95
0,56
.225
0,38
.37†
7
2
approx. .015
JX-95 Straight leaf
9,4
1,95
0,56
.225
0,38
(For higher temp.) .37†
7
2
approx. .015
JX-41** Reverse leaf
Dim. Dwg. Fig. 9
9,4
1,67
0,28
.110
0,38
.37†
6
1
approx. .015
0,64
.025
0,64
.025
0,64
.025
7,5
.295
7,5
.295
7,5
.295
12,3
.485
ref.
12,3
.485
ref.
9,4
.370
ref.
JX-45 Roller leaf
6,1
1,95
0,28
.225
0,38
.24†
7
1
approx. .015
JX-96 Roller leaf
6,1
1,95
0,28
.225
0,38
(For higher temp.) .24†
7
1
approx. .015
JX-51** Reverse roller leaf 7,6
1,67
0,56
.110
0,38
.30†
6
2
approx. .015
0,64
.025
0,64
.025
0,64
.025
Dim. Dwg. Fig. 9
12,2
.480
12,2
.480
12,8
.505
16,5
.650
ref.
16,5
.650
ref.
14,7
.580
ref.
Dim. Dwg. Fig. 10
JX-4
Tandem leaf
7,9
4,17
0,83
.065
0,20
.31
15
3
approx. .008
**Switch is mounted with plunger end reversed
from JX-40.
†‘‘A’’ measurement is from center of mounting
hole nearest tip of lever to the point indicated on
drawing.
NOTE: Above actuators should be used at tem-
peratures below +300°F (149°C); except listings
JX-95, JX-96, JX-219 and JX-220 are for use with
the 4SX1-T to 400°F. (204°C).
0,76
7,6
9,40
.030
.300
.370
ref.
Except where stated †† ±0,76 mm
±.030 in.
24 Honeywell Sensing and Control
For application help: call 1-800-537-6945.