English
Language : 

US10D10A00 Datasheet, PDF (76/94 Pages) Honeywell Solid State Electronics Center – Basic Switches
Basic Switches
Standard
PIN PLUNGER —
SPECIAL CIRCUITRY
BZ/BA Series
Dim. Dwg. Fig. 8
ORDER GUIDE
Catalog Listing
BZ-3AT
BZ-2AW80T
BZ-2AW82T
BZ-2AW822T
Recommended For
Double-break, low
voltage DC applications
As above, with
2.5 inch lever
As above, with
1.9 inch roller lever
As above, with
1.05 inch roller lever
Electrical
Data and
UL Codes
Page 46
O.F. R.F. min. P.T. max. O.T. min.
newtons newtons mm
mm
ounces ounces inches inches
D.T.
mm
inches
O.P.*
mm
inches
15 Amps 4,45-7,23 1,11
T
16-26
4
0,76
.030
0,13
.005
0,051-0,13
.002-.005
15,9
.625
15 Amps
0,90
0,14
–
5,56
0,51
19,05±0,76
T
3.25
.25
–
.219
2.54
.750±.030
15 Amps
1,25
0,21
–
3.96
0,38-1,91 30,18±0,76
T
4.5
.75
–
.156 .015-.075 1.188±.030
15 Amps
2,36
0,42
–
2,39
0,20-2,39 30,18±0,76
T
8.5
1.5
–
.094 .008-.030 1.188±.030
Dim. Dwg. Fig. 9
BA-3ST
Double-break, low
25 Amps 7,23-10,6 2,78
voltage DC applications
M
26-38
10
1,65
.065
0,25
.010
0,18-0,38
.007-.015
16,3
.640
Dim. Dwg. Fig. 10
BZ-3YT
(MS25383-1)
BZ-3YWT80
BZ-3YWT82
BZ-3YWT822
MIL-S-8805 application
requirements. (split
contact)
As above, with
2.50 inch lever
As above, with
1.9 inch roller lever
As above, with
1.05 inch roller lever
5 Amps 4,45-7,23 1,11
U
16-26
4
5 Amps
0,97
0,14
U
3.5
.5
5 Amps
1,25
0,21
U
4.5
.75
5 Amps
1,95
0,42
U
7
1.5
0,76
.030
–
–
–
–
–
–
0,13
.005
0,025-0,1
.001-.004
15,9
.625
5,56
.219
0,51-2,54 19,05±0,76
.020-.100 .750±.030
3,96
.156
0,38-1,91 30,18±0,76
.015-.075 1.188±.030
2,39
.094
0,20-1,02
.008-.040
30,19
.188
Except where stated * ±0,38 mm
±.015 in.
For application help: call 1-800-537-6945.
Honeywell Sensing and Control 57