English
Language : 

US10D10A00 Datasheet, PDF (89/94 Pages) Honeywell Solid State Electronics Center – Basic Switches
Basic Switches
Magnetic Blow-out
MT Series
FEATURES
ɀ Arc resistant case
ɀ Mechanical life of 100,000 operations
— 95% survival
ɀ Temperature tolerance to +180°F
(82°C)
ɀ Mounting interchangeability with Z
switches
ɀ UL recognized
GENERAL INFORMATION
MT (single-pole double-throw) magnetic
blow-out switches are designed to switch
high capacity (125 and 250 VDC) sys-
tems. An integral magnet around the con-
tact gap protects the contacts by deflect-
ing the arc. Vents between the cover and
housing allow the hot gas to escape.
These switches are designed for the con-
trol of DC motors, solenoids, etc.
AVAILABLE TERMINALS
Solder (No listing designation)
ELECTRICAL RATING
Circuitry
Electrical Data and
UL Codes
Single-pole
double-throw
unless
otherwise noted
in order guide
K Rating established with
switch non-polarized
10 amps, 125 vac or vdc;
1/4 hp, 125 vac or vdc.
UL Code L 168
Non-polarized:
10 amps res. or 1/4 hp, 125 vdc;
3 amps max. res. 250 vdc.
Polarized*:
10 amps res. or 1/2 hp, 125 vdc;
3 amps max. res., 250 vdc.
*To polarize, connect negative side of line to common terminal. To
achieve the same effect, mount switch with brass screws, using a
non-magnetic barrier (at least 1⁄4 ⍯ thick) between the switch and
mounting surface.
A28
6-32NC ⍥ .218⍯ Screws
will accept up to #12 wire.
Dim. Dwg. Fig. 1
ORDER GUIDE
Characteristics: O.F. – Operating Force;
R.F. – Release Force; P.T. – Pretravel;
O.T. – Overtravel; D.T. – Differential Travel;
O.P. – Operating Position.
Catalog Listing
MT-4R-A28
Recommended For
Pin plunger
SPDT
Electrical O.F.
Data and newtons
UL Codes ounces
10 Amps 3,34-5,0
K
12-18
R.F. min.
newtons
ounces
1,39
5
P.T. max.
mm
inches
1,02
.04
O.T. min.
mm
inches
0,13
.005
D.T. max.
mm
inches
0,1-0,18
.004-.007
O.P.
mm
inches
15,9±0,38
.625±.015
70 Honeywell Sensing and Control
For application help: call 1-800-537-6945.