English
Language : 

US10D10A00 Datasheet, PDF (32/94 Pages) Honeywell Solid State Electronics Center – Basic Switches
Position Sensors
Environment-Sealed Basic Switches
SE and XE Series
GENERAL INFORMATION
SE and XE switches are the smallest envi-
ronment-sealed switches offered by
MICRO SWITCH. Both types enclose ba-
sic switches within a corrosion resistant
aluminum housing to seal precision
switch contacts from contamination. SE
switches include a SM basic switch, and
XE switches include the smaller SX basic
switch.
Switches held depressed for extended
periods of time at temperature extremes
may experience retarded plunger return
upon deactuation. Where such a condi-
tion exists in the application, contact the
800 number for special designs that are
available.
FEATURES
ɀ Watertight seal per enclosure design
symbol 3, MIL-S-8805
ɀ Power load switching capability up to 7
amps
ɀ Temperature tolerance up to +221°F
(105°C)
ɀ High temperature construction for use
to +300°F (149°C)
ɀ Several auxiliary actuators
ɀ Choice of termination
ɀ Military standard construction with list-
ings qualified to MIL-S-8805
ɀ All 4SE switches are UL recognized
and CSA certified
ɀ 4XE switches are UL recognized
ELECTRICAL RATINGS
Circuitry
Single-Pole
Double-Throw
Electrical Rating Code
A 5 amps res., 3 amps ind., (sea level), 5 amps res.,
2.5 amps ind., (50,000 feet) 28 vdc.
5 amps res., 5 amps ind., 125 or 250 vac, 60 Hz.
D UL Rating
7 amps, 250 vac 60 Hz
B UL and CSA Rating
5 amps, 250 vac, 60 Hz
E 7 amps res., 4 amps ind., (sea level),
7 amps res., 2.5 amps ind., (50,000 feet), 28 vdc.
C 7 amps res., 4 amps ind., (sea level),
7 amps res., 2.5 amps ind., (50,000 feet), 28 vdc.
7 amps res., 4 amps ind., (sea level), 115 vac, 400 Hz
R 1 amp res., 0.50 amp ind., 28 vdc.
SE SWITCHES ORDER GUIDE
1 foot leads
(other lengths
available)
Fig. 1
Catalog
Listing
1SE1
Recommended
For
Most applications
1SE2
1SE3
4SE1
5SE1
7SE1
SPST — Normally-
closed
SPST — Normally-
open
UL and CSA listing
and UL and CSA
listed lead wire
Oil resistant
Fluorosilicone seal
Lower force
12SE4-T High return force
1SE1-T
For customer
leading
Characteristics: O.F. — Operating Force; R.F. — Release Force;
P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel;
O.P. — Operating Position
Electrical
Rating
Code
A
A
A
B
O.F.
Newtons
ounces
1,39-4,73
5-17
1,39-4,73
5-17
1,39-4,73
5-17
1,39-4,73
5-17
R.F. min.
Newtons
ounces
1,11
4
1,11
4
1,11
4
1,11
4
Characteristics
P.T. max. O.T. min.
mm
mm
inches inches
1,27
0,08
.050
.003
1,27
0,08
.050
.003
1,27
0,08
.050
.003
1,27
0,08
.050
.003
D.T. max.
mm
inches
0,1
.004
0,1
.004
0,1
.004
0,1
.004
O.P.
mm
inches
10,8
.425
10,8
.425
10,8
.425
10,8
.425
A
1,39-4,73 1,11
1,27
0,08
0,1
10,8
5-17
4
.050
.003
.004
.425
A
1,11-2,22 0,56
1,27
0,08
0,1
10,8
4-8
2
.050
.003
.004
.425
A
1,39-5,28 1,11
1,27
0,08
0,1
10,8
5-19
4
.050
.003
.004
.425
A
1,39-4,73 1,11
1,27
0,08
0,1
10,8
5-17
4
.050
.003
.004
.425
Fig. 2
Honeywell Sensing and Control ɀ 1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ 1-416-293-8111 Canada 13