GS4576C09/18/36L
Input Slew Rate Derating
The Address and Command Setup and Hold Derating Values shown in the following table should be added to the default tAS/tCS/
tDS and tAH/tCH/tDH specifications when the slew rate of any of these input signals is less than the 2 V/ns.
To determine the setup and hold time needed for a given slew rate, add the tAS/tCS default specification to the “tAS/tCS VREF to
CK/CK Crossing” and the tAH/tCH default specification to the "tAH/tCH CK/CK Crossing to VREF" derated values in the Address
and Command Setup and Hold Derating Values table. The derated data setup and hold values can be determined the same way
using the “tDS VREF to CK/CK Crossing” and “tDH to CK/CK Crossing to VREF” values in the Data Setup and Hold Derating
Values table. The derating values apply to all speed grades.
The setup times in the table relate to a rising signal. The time from the rising signal crossing VIH(AC)MIN to the CK/CK cross point
is static and must be maintained across all slew rates. The derated setup timing describes the point at which the rising signal crosses
VREF(DC) to the CK/CK cross point. This derated value is calculated by determining the time needed to maintain the given slew
rate and the delta between VIH(AC)MIN and the CK/CK cross point. All these same values are also valid for falling signals (with
respect to VIL(AC)MAX and the CK/ CK cross point).
The hold times in the table relate to falling signals. The time from the CK/CK cross point to when the signal crosses VIH(DC) MIN is
static and must be maintained across all slew rates. The derated hold timing describes the delta between the CK/CK cross point to
when the falling signal crosses VREF(DC). This derated value is calculated by determining the time needed to maintain the given
slew rate and the delta between the CK/CK cross point and VIH(DC). The hold values are also valid for rising signals (with respect
to VIL(DC)MAX and the CK and CK cross point).
Note: The above descriptions also pertain to data setup and hold derating when CK/CK are replaced with DK/DK.
Rev: 1.04 11/2013
42/62
Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
© 2011, GSI Technology