English
Language : 

GX4002 Datasheet, PDF (9/74 Pages) Gennum Corporation – Dynamic on-chip power management control
Table 2-1: DC Electrical Characteristics (Continued)
VCC = +2.8V to +3.47V, TC = -40°C to 100°C. Typical values are VCC = +3.3V and TA = 25°C, unless otherwise specified.
Specifications assume default setting to end-terminated 50Ω transmission lines, unless otherwise stated. Typical Data Rate = 14.025Gb/s
Note: mApp refers to mA peak-to-peak value.
Parameter
Conditions
Symbol
Min
Typ
Max
Units Notes
Channel 0 Specifications
Input Termination (SDI0)
Differential
Output Termination (SDO0)
80
100
120
Ω
—
—
50
—
Ω
—
Channel 1 Specifications
Input Termination
(Ch1SDIP/N)
Differential
80
100
120
Ω
—
Output Termination
(Ch1SDOP/N)
Differential
80
100
120
Ω
—
NOTES:
1. Typical Conditions: T = 25°C, V = 3.3V. Maximum Conditions: T = 100°C, V = 3.467V.
2. Each output terminated.
2.2.1 Power Features
Table 2-2: Power Features
Configuration
GX4002 Base
SDO1 Pre-emphasis = 3dB @ 600mVppd
PRBS7 Generator
PRBS7 Checker
Diag + ADC
Eye Monitor + ADC
Ch0 EQ Boost
GX4002 with Ch0 CDR bypassed and
powered-down
GX4002 with Ch1 & Ch0 CDR bypassed and
powered-down
Typical
Baseline
Power
(mW)
600
—
—
—
—
—
—
—
Typical
Incremental
Power
(mW)
Description
20
115
125
14
50
0
-90mW
—
Path for PRBS7 generator to
Ch1SDO is on.
PRBS7 checker is on.
Temperature, Supply Sensor, ADC.
All, Ch0 and Ch1 horizontal and
vertical eye monitors are on.
—
—
Feature
Section
3.3.4
3.6.1
3.6.1
3.7
3.6.2
3.2.1
—
—
-185mW
—
—
GX4002 2x2 14.025Gb/s Crosspoint Switch with Trace
Equalization and Output De-Emphasis
Data Sheet
55972 - 0
March 2012
9 of 74
Proprietary & Confidential