GX4002 Datasheet, PDF (11/74 Pages) Gennum Corporation – Dynamic on-chip power management control | |||
|
◁ |
Table 2-3: AC Electrical Characteristics (Continued)
VCC = +2.8V to +3.47V, TC = -40°C to 100°C. Typical values are VCC = +3.3V and TA = 25°C, unless otherwise specified.
Specifications assume default setting to end-terminated 50Ω transmission lines, unless otherwise stated. Typical Data Rate = 14.025Gb/s
Parameter
Conditions
Symbol
Min
Typ
Max
Units Notes
1 sigma, IC to IC
â
1.50
â
mVrms
â
Ch1LOS Threshold Level
Variation
over VCC Range
over temperature
range -40°C to
+100°C
â
+0.5
â
dB
â
â
+0.5
â
dB
â
Ch1LOS Threshold Level
Hysteresis Setting Range
electrical
0
â
6
dB
â
Ch1LOS Response Time
3
5
20
μs
â
Ch1 CDR Lock Time
16G FC mode: loop
filter cap = 100nF
â
â
0.5
ms
4
Differential Output Voltage
Setting Range
minimum swing
setting
maximum swing
setting
â
100
â
mVppd
â
â
850
â
mVppd
â
Output Pre-emphasis
Setting Range
maximum setting
3
â
â
dB
5
NOTES:
1. See Table 3-1 for details.
2. At 7GHz.
3. 600mVppd swing.
4. For loop bandwidth = 13MHz (as detailed in Table 3-4).
5. 600mVppd swing.
6. At 7GHz (dielectric loss).
7. Reg89[7:0] = "11001000" = Reg110[7:0]. Reg90[1:0] = "00" = Reg111[7:0]. Reg102[1:0] = "00". Reg118[4:3] = "11" = Reg119[4:3].
Reg80[7:0] = "11101110". Reg81[4:0] = "11100" = Reg103[4:0]. Reg82[4:0] = "11010" = Reg104[4:0].
8. Reg89[7:0] = "11111111" = Reg110[7:0]. Reg90[1:0] = "11" = Reg111[7:0]. Reg102[1:0] = "00". Reg118[4:3] = "00" = Reg119[4:3].
Reg80[7:0] = "01000100". Reg81[4:0] = "01000" = Reg103[4:0]. Reg82[4:0] = "10000" = Reg104[4:0].
GX4002 2x2 14.025Gb/s Crosspoint Switch with Trace
Equalization and Output De-Emphasis
Data Sheet
55972 - 0
March 2012
11 of 74
Proprietary & Confidential
|
▷ |