English
Language : 

MB82DBS08164D-70L Datasheet, PDF (19/60 Pages) Fujitsu Component Limited. – 128 M Bit (8 M word x 16 bit) Mobile Phone Application Specific Memory
MB82DBS08164D-70L
2. AC Characteristics
(1) Asynchronous Read Operation
Parameter
Read Cycle Time
CE1 Access Time
OE Access Time
Address Access Time
ADV Access Time
LB, UB Access Time
Output Data Hold Time
CE1 Low to Output Low-Z
OE Low to Output Low-Z
LB, UB Low to Output Low-Z
CE1 High to Output High-Z
OE High to Output High-Z
LB, UB High to Output High-Z
Address Setup Time to ADV Low
Address Setup Time to CE1 Low
Address Setup Time to OE Low
ADV Low Pulse Width
ADV High Pulse Width
Address Hold Time from ADV High
Address Invalid Time
Address Hold Time from CE1 High
Address Hold Time from OE High
WE High to OE Low Time for Read
CE1 High Pulse Width
(At recommended operating conditions unless otherwise noted)
Value
Symbol
Unit
Notes
Min
Max
tRC
70
1000
ns *1, *2
tCE
⎯
70
ns *3
tOE
⎯
40
ns *3
tAA
⎯
70
ns *3, *4
tAV
⎯
70
ns *3
tBA
⎯
30
ns *3
tOH
3
⎯
ns *3
tCLZ
10
⎯
ns *5
tOLZ
10
⎯
ns *5
tBLZ
10
⎯
ns *5
tCHZ
⎯
9.5
ns *3
tOHZ
⎯
9.5
ns *3
tBHZ
⎯
9.5
ns *3
tASVL
−5
⎯
ns *6
tASC
−5
⎯
ns *6
tASO
0
⎯
ns
tVPL
7
⎯
ns *6
tVPH
10
⎯
ns
tAHV
5
⎯
ns
tAX
⎯
10
ns *4, *7
tCHAH
−5
⎯
ns *8
tOHAH
−5
⎯
ns
tWHOL
10
1000
ns *9
tCP
10
⎯
ns
*1 : Maximum value is applicable if CE1 is kept at Low without change of address input.
*2 : Address should not be changed within a minimum tRC.
*3 : The output load 50 pF with 50 Ω termination to VDD × 0.5 V.
*4 : Applicable when CE1 is kept at Low.
*5 : The output load 5 pF without any other load.
*6 : tVPL is specified from the falling edge of either CE1 or ADV whichever comes late. The sum of actual tVPL and
tASVL (or tASC) must be equal or greater than the specified minimum value of tVPL.
*7 : Applicable to address access when at least two of address inputs are switched from the previous state.
*8 : tRC (Min) must be satisfied.
*9 : If actual value of tWHOL is shorter than specified minimum values, the actual tAA of following Read may become
longer by the amount of subtracting actual value from specified minimum value.
DS05-11454-1E
19