English
Language : 

908E621_08 Datasheet, PDF (36/65 Pages) Freescale Semiconductor, Inc – Integrated Quad Half-bridge and Triple High Side with Embedded MCU and LIN for High End Mirror
FUNCTIONAL DEVICE OPERATION
OPERATIONAL MODES
VDD
10k
H0PD
H0MS
VSUP
H0MS
H0F
H0EN
H0
H0EN
Current
Sense
Figure 18. General purpose / Hall-effect Sensor Input (H0)
Current Coded Hallsensor Input
H0 is selected as “2-pin hallsensor input”, if the
corresponding H0MS bit in the H0/L0 Status and Control
Register (HLSCTL) is set. In this mode, the pin current to
GND is monitored by a special sense circuitry. Setting the
H0EN bit in the H0/L0 Status and Control Register, switches
the output to VSUP and enables the sense circuitry. The
result of the sense operation is given by the H0F flag. The
flag is low if the sensed current is higher than the sense
current threshold IHSCT. In this configuration, the HO pin is
protected (current limitation) against short-circuit to GND.
After switching on the hallport (H0EN = “1”), the hallsensor
needs some time to stabilize the output. In RUN mode, the
software has to take care about waiting for a few µs (40)
before sensing the hallflags.
The hallport output current is sensed. In case of an over-
current (short to GND), the hallport over-current flag
(H0OCF) is set and the current is limited. For proper
operation of the current limitation, an external capacitor
(>100nF) close to the H0 pin is required.
VSUP
H0EN
H0F
Current
Sense
V
2 pin hall sensor
H0
>0.1uF
GND
908E621
36
Figure 19. H0 Used as 2-pin Hallsensor Input
Analog Integrated Circuit Device Data
Freescale Semiconductor