English
Language : 

MC9S12DT128CPVE Datasheet, PDF (109/128 Pages) Freescale Semiconductor, Inc – Device User Guide
Freescale SemicondMuC9cSt1o2DrT,1I2n8BcD.evice User Guide — V01.09
A.5.3 Phase Locked Loop
The oscillator provides the reference clock for the PLL. The PLL´s Voltage Controlled Oscillator (VCO)
is also the system clock source in self clock mode.
A.5.3.1 XFC Component Selection
This section describes the selection of the XFC components to achieve a good filter characteristics.
Cp
VDDPLL
Cs
R
Phase
XFC Pin
VCO
fosc
1
fref
refdv+1
∆
KΦ
KV
fvco
Detector
fcmp
Loop Divider
1
1
synr+1
2
Figure A-2 Basic PLL functional diagram
The following procedure can be used to calculate the resistance and capacitance values using typical
values for K1, f1 and ich from Table A-16.
The grey boxes show the calculation for fVCO = 50MHz and fref = 1MHz. E.g., these frequencies are used
for fOSC = 4MHz and a 25MHz bus clock.
The VCO Gain at the desired VCO frequency is approximated by:
KV = K1 ⋅ e-(--fK--1--1--–--⋅--f-1-v--c-V--o=--)- –120 ⋅ e(---7---–5---1--–--2---50---0--=--) -97.43MHz/V
The phase detector relationship is given by:
KΦ = – ich ⋅ KV
= 341.0Hz/Ω
ich is the current in tracking mode.
For More Information On This Product,
Go to: www.freescale.com