English
Language : 

LM3S1958 Datasheet, PDF (256/435 Pages) List of Unclassifed Manufacturers – Microcontroller
Analog-to-Digital Converter (ADC)
Register 5: ADC Overflow Status (ADCOSTAT), offset 0x010
This register indicates overflow conditions in the Sample Sequencer FIFOs. Once the overflow
condition has been handled by software, the condition can be cleared by writing a 1 to the
corresponding bit position.
ADC Overflow Status (ADCOSTAT)
Base 0x4003.8000
Offset 0x010
Type R/W1C, reset 0x0000.0000
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
reserved
Type RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
reserved
OV3
OV2
OV1
OV0
Type RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO R/W1C R/W1C R/W1C R/W1C
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit/Field
31:4
3
2
1
0
Name
reserved
OV3
OV2
OV1
OV0
Type
RO
R/W1C
R/W1C
R/W1C
R/W1C
Reset
0
0
0
0
0
Description
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
This bit specifies that the FIFO for Sample Sequencer 3 has hit an
overflow condition where the FIFO is full and a write was requested.
When an overflow is detected, the most recent write is dropped and this
bit is set by hardware to indicate the occurrence of dropped data. This
bit is cleared by writing a 1.
This bit specifies that the FIFO for Sample Sequencer 2 has hit an
overflow condition where the FIFO is full and a write was requested.
When an overflow is detected, the most recent write is dropped and this
bit is set by hardware to indicate the occurrence of dropped data. This
bit is cleared by writing a 1.
This bit specifies that the FIFO for Sample Sequencer 1 has hit an
overflow condition where the FIFO is full and a write was requested.
When an overflow is detected, the most recent write is dropped and this
bit is set by hardware to indicate the occurrence of dropped data. This
bit is cleared by writing a 1.
This bit specifies that the FIFO for Sample Sequencer 0 has hit an
overflow condition where the FIFO is full and a write was requested.
When an overflow is detected, the most recent write is dropped and this
bit is set by hardware to indicate the occurrence of dropped data. This
bit is cleared by writing a 1.
256
June 14, 2007
Luminary Micro Confidential-Advance Product Information