SI8421AD Datasheet, PDF (22/37 Pages) List of Unclassifed Manufacturers – LOW-POWER, SINGLE AND DUAL-CHANNEL DIGITAL ISOLATORS
Si8410/20/21 (5 kV)
Si8422/23 (2.5 & 5 kV)
3. Device Operation
Device behavior during start-up, normal operation, and shutdown is shown in Figure 7, where UVLO+ and UVLO-
are the positive-going and negative-going thresholds respectively. Refer to Table 12 to determine outputs when
power supply (VDD) is not present.
Table 12. Si84xx Logic Operation Table
VI Input1,4 VDDI State1,2,3 VDDO State1,2,3 VO Output1,4
Comments
H
P
P
L
P
P
H
Normal operation.
L
X5
UP
X5
P
P
H6 (Si8422/23) Upon transition of VDDI from unpowered to
L6 (Si8410/20/21) powered, VO returns to the same state as VI in
less than 1 µs.
UP
Undetermined Upon transition of VDDO from unpowered to
powered, VO returns to the same state as VI
within 1 µs.
Notes:
1. VDDI and VDDO are the input and output power supplies. VI and VO are the respective input and output terminals.
2. Powered (P) state is defined as 2.72.60 V < VDD < 5.5 V.
3. Unpowered (UP) state is defined as VDD = 0 V.
4. X = not applicable; H = Logic High; L = Logic Low.
5. Note that an I/O can power the die for a given side through an internal diode if its source has adequate current.
6. See "6. Ordering Guide" on page 29 for details. This is the selectable fail-safe operating mode (ordering option). Some
devices have default output state = H, and some have default output state = L, depending on the ordering part number
(OPN).