SI8421AD Datasheet, PDF (16/37 Pages) List of Unclassifed Manufacturers – LOW-POWER, SINGLE AND DUAL-CHANNEL DIGITAL ISOLATORS
Si8410/20/21 (5 kV)
Si8422/23 (2.5 & 5 kV)
Table 5. Recommended Operating Conditions
Parameter
Symbol
Min
Typ
Max
Unit
Ambient Operating Temperature*
TA
–40
25
125
C°
Supply Voltage
VDD1
2.70
—
5.5
V
VDD2
2.70
—
5.5
V
*Note: The maximum ambient temperature is dependent upon data frequency, output loading, the number of operating
channels, and supply voltage.
Table 6. Regulatory Information*
CSA
The Si84xx is certified under CSA Component Acceptance Notice 5A. For more details, see File 232873.
61010-1: Up to 600 VRMS reinforced insulation working voltage; up to 600 VRMS basic insulation working voltage.
60950-1: Up to 600 VRMS reinforced insulation working voltage; up to 1000 VRMS basic insulation working volt-
age.
60601-1: Up to 125 VRMS reinforced insulation working voltage; up to 380 VRMS basic insulation working voltage.
VDE
The Si84xx is certified according to IEC 60747-5-5. For more details, see File 5006301-4880-0001.
60747-5-5: Up to 891 Vpeak for basic insulation working voltage.
60950-1: Up to 600 VRMS reinforced insulation working voltage; up to 1000 VRMS basic insulation working volt-
age.
UL
The Si84xx is certified under UL1577 component recognition program. For more details, see File E257455.
Rated up to 5000 VRMS isolation voltage for basic insulation.
*Note: Regulatory Certifications apply to 2.5 kVRMS rated devices which are production tested to 3.0 kVRMS for 1 sec.
Regulatory Certifications apply to 5.0 kVRMS rated devices which are production tested to 6.0 kVRMS for 1 sec.
For more information, see "6. Ordering Guide" on page 29.
16
Rev. 1.3